본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

인공수정체 도수 산출 공식간 오차에 영향을 미치는 요인 분석

이용수 6

영문명
Analysis of Factors that Influence on Accuracy of Intraocular Lens Power Calculation
발행기관
대한안과학회
저자명
김보혁 위원량 김미금,Bo Hyuck Kim, MD, Won Ryang Wee, MD, PhD, Mee Kum Kim, MD, PhD,
간행물 정보
『대한안과학회지』Ophthalmological Society,volume55,number2, 173~181쪽, 전체 9쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2014.02.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To investigate which factors primarily influence refractory errors between various formulas used to calculate intraocular lens (IOL) power. Methods: Records of 266 eyes of 191 patients who underwent uneventful cataract surgery were reviewed retrospectively. IOL power was determined using SRK/T, HofferQ (H/Q), Master SRK/T (M/T), Master HofferQ (M/Q), Master Holladay (M/Hol), and Master Haigis (M/Hai). The mean absolute error (MAE) of each formula was compared; MAE was defined as the difference between the postoperative spherical equivalence (SE) determined 1 month after surgery and the predicted SE. Factors that could have influenced interformula refractive errors were analyzed. Patients were divided into 3 groups based on average keratometric value (Kavg) and the inter-group differences of the AE of each formula were analyzed. Effects of corneal curvature on changes in AE of each formula were evaluated by linear regression. Results: The MAE was minimized in the M/T formula, followed by the M/Hol, M/Hai, SRK/T, H/Q, and M/Q formulas. Interformula MAE differences were not statistically significant. Kavg and AXL were significantly influenced by the different predictive values between formulas in univariate analysis, but only AXL was significant in multivariate analysis. The AE in each formula among the 3 groups according to keratometry was significantly different in SRK, M/Hol, and M/Hai. Linear regression analysis showed a significant negative correlation between Kavg, AE of SRK/T and the MHai formula. In particular, this effect was more pronounced in those with short AXL (<22.5 mm). Conclusions: There were no significant MAE differences between formulas. AXL was a significant factor that influenced the differences between formulas. SRK/T and M/Hai may be affected by outside the normal range of corneal curvatures. J Korean Ophthalmol Soc 2014;55(2):173-181

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김보혁,위원량,김미금,Bo Hyuck Kim, MD, Won Ryang Wee, MD, PhD, Mee Kum Kim, MD, PhD,. (2014).인공수정체 도수 산출 공식간 오차에 영향을 미치는 요인 분석. 대한안과학회지, 55 (2), 173-181

MLA

김보혁,위원량,김미금,Bo Hyuck Kim, MD, Won Ryang Wee, MD, PhD, Mee Kum Kim, MD, PhD,. "인공수정체 도수 산출 공식간 오차에 영향을 미치는 요인 분석." 대한안과학회지, 55.2(2014): 173-181

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제