본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

안구 길이와 전방 깊이에 따른 Haigis 공식의 정확성

이용수 2

영문명
Accuracy of the Haigis Formula Based on Axial Length and Anterior Chamber Depth
발행기관
대한안과학회
저자명
이찬희 최성호 정의상 정태영,Chan-Hui Yi, MD, Sung-Ho Choi, MD, Eui-Sang Chung, MD, PhD, Tae-Young Chung, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume52,number2, 175~181쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2011.02.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the effect of axial length (AXL) and anterior chamber depth (ACD) on the accuracy of the Haigis formula in comparison to its effect on other 3rd generation IOL power calculations. The possibility of measurement error in ACD using either method was also investigated. Methods: A study was performed on 137 eyes of 98 patients who underwent cataract surgery in our hospital. AXL and ACD were measured using IOL Master, and IOL power was calculated using the Haigis, SRK/T, Hoffer Q, and Holladay 1 formulas. ACD was also measured using Pentacam. Patients were divided into 3 groups based on ACD and AXL. Mean numeric error and mean absolute error were analyzed 1 month after surgery. Results: Five formulae showed no significant difference in refractive error in the 3 groups based on AXL. In contrast, the Haigis formula showed statistically significant differences in the group with shallow ACD, in which hyperopic shift was also demonstrated. The difference in ACD between using IOL Master and using Pentacam was significant in the shallow ACD group, with IOL Master showing more shallow measurement. However, the other groups based on ACD showed no significant difference in the refractive error from the Haigis formula, and in the difference in ACD between measurements. Conclusions: Errors in ACD measurement should be taken into consideration for discrepancy between the Haigis formula measurement and other formula measurements. The authors of the present study suggest that ACD-driven refractive error should be considered in determination of IOL. J Korean Ophthalmol Soc 2011;52(2):175-181

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이찬희,최성호,정의상,정태영,Chan-Hui Yi, MD, Sung-Ho Choi, MD, Eui-Sang Chung, MD, PhD, Tae-Young Chung, MD, PhD. (2011).안구 길이와 전방 깊이에 따른 Haigis 공식의 정확성. 대한안과학회지, 52 (2), 175-181

MLA

이찬희,최성호,정의상,정태영,Chan-Hui Yi, MD, Sung-Ho Choi, MD, Eui-Sang Chung, MD, PhD, Tae-Young Chung, MD, PhD. "안구 길이와 전방 깊이에 따른 Haigis 공식의 정확성." 대한안과학회지, 52.2(2011): 175-181

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제