본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

한국인에서 가변각막보정 주사레이저편광측정계의 진단적 유용성

이용수 8

영문명
Diagnostic Ability of Scanning Laser Polarimetry with Enhanced Corneal Compensation in the Eye with Typical and Atypical Retadation Pattern
발행기관
대한안과학회
저자명
이창환 권용혁 최재완 국문석,Chang Hwan Lee, M.D., Yong Hyuk Kwon, M.D., Jae Wan Choi, M.D., Michael S. Kook, M.D.
간행물 정보
『대한안과학회지』Ophthalmological Society,volume48,number3, 392~398쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2007.03.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To investigate the relationship between the SLP-VCC parameters and the SLP-ECC parameters in the eyes with typical retardation pattern (TRP) and atypical retardation pattern (ARP), and the sensitivities and specificities of the SLP-VCC parameters and the SLP-ECC parameters in the eye with TRP and ARP. Methods: In this prospective study, 72 eyes with TRP images (30 glaucomatous and 42 normal eyes) and 53 eyes with ARP images (28 glaucomatous and 25 normal eyes) were recruited. For each group, we analyzed relationship between each parameters of GDx-VCC and GDx-ECC and the diagnostic ability of GDx-ECC by using the ROC curve. Results: In the eyes with TRP, TSNIT average was significantly lower by GDx-ECC than GDx-VCC in the control group. Inferior average was significantly higher by GDx-ECC than GDx-VCC in both glaucomatous and normal group. TSNIT standard deviation was significantly higher by GDx-ECC than GDx-VCC in both groups. NFI was significantly lower by GDx-ECC than GDx-VCC in both groups. TSS (typical scan score) was significantly higher by GDx-ECC than GDx-VCC in both groups. In the eyes with ARP, TSNIT average was significantly lower by GDx-ECC than GDx-VCC in both groups. Superior and Inferior average was not different between GDx-ECC and GDx-VCC. TSNIT standard deviation was significantly higher by GDx-ECC than GDx-VCC in both groups. NFI was not different between groups. TSS was significantly higher by GDx-ECC than GDx-VCC in both groups. Comparison of ROC curve for the SLP parameters revealed no difference between VCC and ECC. TSNIT standard deviation, however, showed relatively high value in GDx-ECC compared with GDx-VCC. Conclusions: GDx-ECC has comparable diagnostic ability in discriminating glaucomatous and normal eyes with GDx-VCC and TSNIT standard deviation by the GDx-ECC algorithm could be a useful parameter in discriminating glaucomatous and normal eyes.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이창환,권용혁,최재완,국문석,Chang Hwan Lee, M.D., Yong Hyuk Kwon, M.D., Jae Wan Choi, M.D., Michael S. Kook, M.D.. (2007).한국인에서 가변각막보정 주사레이저편광측정계의 진단적 유용성. 대한안과학회지, 48 (3), 392-398

MLA

이창환,권용혁,최재완,국문석,Chang Hwan Lee, M.D., Yong Hyuk Kwon, M.D., Jae Wan Choi, M.D., Michael S. Kook, M.D.. "한국인에서 가변각막보정 주사레이저편광측정계의 진단적 유용성." 대한안과학회지, 48.3(2007): 392-398

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제