본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

水泳訓鍊이 體脂肪, 運動遂行 能力에 미치는 效果

이용수 9

영문명
The Effect on Swimming Training on Body Composition, Strength and Heart-Rate
발행기관
경희대학교 스포츠과학연구원
저자명
高東信(Ko Dong Shin) 兪承熙(Yoo Seung Hee)
간행물 정보
『체육학논문집』제19집, 33~47쪽, 전체 15쪽
주제분류
예술체육 > 체육
파일형태
PDF
발행일자
1991.12.01
4,600

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

  The objective of this study is to ascertain the effects that swimming has on physical structure, physical strength, and athletic performance capacity.
  The traning group was composed of ten student members of the "K" University amateur swim team while the comparative group was composed of ten ordinary students. The training roup, with the exception of Sundays, trained for about an hour daily for a period of six weeks.
  Inorder to ascertain physical structure, the thickness of subcutaneous fat, percentage of bodyfat, and weight of body fat were measured. Finally, to ascertain the change in athletic performance capacity, heart rate, athletic endurance, and time till appearance of PWC170 were measured using a cycle ergometer.
  The first measurements were taken before the experiment. The second measurements were taken after three weeks. The last measurements were taken after six weeks. The following resurts were obtained after analyzing the measurement data:
  1) The swimming group, as compared to the control group, decreased the thickness of subcetaneous fat, percentage of bodyfat.
  2) Excecising abiligty time of the control group and the training group average (8.07, 8.22 min) at first, The control group averaged (3.97) rose and decreased (1.61%), but the swimming group’s average was(1.22%) and continue rose (3.28%) after three, six weeks.
  3) PWC 170 of the control group and the swimming group averaged (6.32, 6.30 min) at first. The control group averaged (1.90%) rose and decreased (-0.79), but the training group’s average was(1.99%) and continue rose (5.11%) after three, six weeks.
  4) General heart-beat of the control group and the swimming group averaged (72.20, 71.80 beat/min) at first.
  The control group averaged (0.55%) rose and decreased (-1.39) and continue decreased (-4.57) after three, six weeks.
  5) The best heart-beat of the control group and the swimming group averaged (192.20, 191.60 beat/min) at first.
  The control group averaged (0.41%) rose and decreased (-0.52), but the swimming group’s average was (-3.40) and continue decreased (-1.77) after three, six weeks.
  6) The swimming group, as comparsed to the comparative group, showed a striking reduction in heart rate both during activity and at rest.
  Synthesizing the above resurt it is found that not only was the scope of the swimming group’s improvement of physical strength comparatively large, but also that they showed reduction in body fat. Further more, their normal and maximum heartbeat, either active or at rest was reduced.
  Finally, they both increased their athletic endurance and time till appearance of PWC170.

목차

ABSTRACT
Ⅰ. 緖論
Ⅱ. 硏究對象 및 方法
Ⅲ. 硏究成績
Ⅳ. 考察
Ⅴ. 結論
參考文獻

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

高東信(Ko Dong Shin),兪承熙(Yoo Seung Hee). (1991).水泳訓鍊이 體脂肪, 運動遂行 能力에 미치는 效果. 체육학논문집, 19 , 33-47

MLA

高東信(Ko Dong Shin),兪承熙(Yoo Seung Hee). "水泳訓鍊이 體脂肪, 運動遂行 能力에 미치는 效果." 체육학논문집, 19.(1991): 33-47

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제