Purpose: This study compared the accuracy of different elastomeric impression materials with open tray implant level impression technique in a single-tooth replacement. Materials and Methods: A reference model representing a single implant with an adjacent simulated natural tooth was fabricated. Open tray implant level impressions were made with vinylpolysiloxane (light body ExpressXT, PentaputtyPentamix2, 3MESPE, Seinfield, Germany) (Group I, n=10) and polyether (medium body Impregnum Penta, Pentamix 2, 3MESPE, Seinfield, Germany), (Group II, n=10) and implant crowns were fabricated on each master cast from their respective impressions by CNC milling and connected to the reference model with 35 Ncm torque. The accuracy of the fit was evaluated by measuring the interface gap between the implant crown and the implant replica at the mesial and distal points and by measuring the proximal gap between the implant crown and the simulated natural tooth at the buccal and the palatal points by scanning electron microscopy for each test sample. The mean values were obtained and statistically analyzed using a Mann-Whitney test. Results: The interface gap observed at the mesial point was significantly higher than the distal point. The proximal gap observed at the palatal point was significantly higher than the buccal point for both Group I and Group II. A comparison of the groups showed that the interface gap at the mesial point and the proximal gap at the buccal and palatal points obtained from polyether impression material were lower than those observed with vinylpolysiloxane group, but the difference was not significant. However, the interface gap observed at the distal point was higher with the polyether group than with the vinylpolysiloxane group, but the difference was not significant. Conclusions: Polyether and vinylpolysiloxane can be used to produce open tray implant impressions for a single missing tooth.

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
CONCLUSION
ORCID
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Abinaya Sekar,Saravanakumar Mariappan,Chitra Shankar Krishnan,Jayakrishnakumar Sampathkumar. (2022).Evaluation of accuracy of different elastomeric materials in open tray implant level technique for single tooth impressions. Journal of Dental Implant Research, 41 (4), 91-101

MLA

Abinaya Sekar,Saravanakumar Mariappan,Chitra Shankar Krishnan,Jayakrishnakumar Sampathkumar. "Evaluation of accuracy of different elastomeric materials in open tray implant level technique for single tooth impressions." Journal of Dental Implant Research, 41.4(2022): 91-101

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제