Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

이용수 6

영문명
Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement
발행기관
물리치료재활과학회
저자명
Young Jae Park Ho Young Jang Kwon Hoi Kim Dong Ki Hwang Suk Min Lee
간행물 정보
『Physical Therapy Rehabilitation Science』제11권 제3호, 311~320쪽, 전체 10쪽
주제분류
의약학 > 재활의학
파일형태
PDF
발행일자
2022.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson’s correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.

목차

Introduction
Method
Result
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Young Jae Park,Ho Young Jang,Kwon Hoi Kim,Dong Ki Hwang,Suk Min Lee. (2022).Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement. Physical Therapy Rehabilitation Science, 11 (3), 311-320

MLA

Young Jae Park,Ho Young Jang,Kwon Hoi Kim,Dong Ki Hwang,Suk Min Lee. "Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement." Physical Therapy Rehabilitation Science, 11.3(2022): 311-320

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제