본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

A 9-year retrospective clinical study of locking taper implants of SNUCONE??

이용수 3

영문명
발행기관
대한치과이식임플란트학회
저자명
Hyeongi Yi Soo Nam Yang Youngkwon Kim Uiesub Shim Jisang Jeong
간행물 정보
『Journal of Dental Implant Research』제38권 제1호, 13~18쪽, 전체 6쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2019.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Among the components of the dental implant, there are various designs and combinations of implant fixtures and abutments. SF implants (Snucone co., Ltd. Korea) are tapered fixtures using a locking tapered abutment. The purpose of this retrospective study was to evaluate cumulative survival rate (CSR) of SF fixture (Snucone co., Ltd. Korea) followed for 9 years. Materials and Methods: From December 2008 to October 2009, 37 patients with 86 SF implants of Snucone?? who had surgery at Chungju Hankook hospital and the follow-up period was nine years. The patients’ gender, age, position of implanted fixtures, diameter and length of implants, bone graft, duration from implantation to secondary operation, the changes of marginal bone around the implant and the survival rate were analyzed. Results: A total of 37 patients, there were 19 male (51.4%) and 18 female (48.6%). Patient ages ranged from 30s to 70s. Of the 86 implants, 36 (41.9%) were placed in the maxilla and 50 (58.1%) were placed in the mandible. The diameter of the most placed implants was 5.3 mm (34.9%) and the length was 8.0 mm (39.5%). Moreover, 59 (68.6%) implants were implanted with bone graft of the total 86 implants. The average period from implant placement to secondary surgery was 5 months. The survival rate of the implant was 98.8% and the average marginal bone resorption was measured −0.95±1.84 mm. Conclusions: Although SF implants of Snucone?? show favorable clinical outcomes with high survival rate and lower marginal bone resorption during the 9-year follow-up period as compared to previous reports, cumulative evaluations and researches should be conducted in the future.

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
CONCLUSION

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Hyeongi Yi,Soo Nam Yang,Youngkwon Kim,Uiesub Shim,Jisang Jeong. (2019).A 9-year retrospective clinical study of locking taper implants of SNUCONE??. Journal of Dental Implant Research, 38 (1), 13-18

MLA

Hyeongi Yi,Soo Nam Yang,Youngkwon Kim,Uiesub Shim,Jisang Jeong. "A 9-year retrospective clinical study of locking taper implants of SNUCONE??." Journal of Dental Implant Research, 38.1(2019): 13-18

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제