학술논문
고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구
이용수 2
- 영문명
- 발행기관
- 대한치과이식임플란트학회
- 저자명
- 고현 박남수
- 간행물 정보
- 『Journal of Dental Implant Research』제12권 제1호, 58~88쪽, 전체 31쪽
- 주제분류
- 의약학 > 의학일반
- 파일형태
- 발행일자
- 1992.12.31
6,520원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
The purpose of this study was to analyze the deflection and stress distribution at the supporting bone
and it’s superstructure by the alteration of angulation between implant and it’s implant abutment. For this
study, the free-end saddle case of mandibular first and second molar missing would be planned to restore
with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder
type osseointegrated implant was placed at the site of mandibular second molar for abutment.
The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were
created, a standard model at 0° and 12 models created by changing the angulation between implant and
implant abutment as increasing the angulation mesially and distally with 5° unittill 30°. The preprocessing,
decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and
SUN — SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load
1) and distributed load (load 2) at the reference points.
The results were as follows :
1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under
concentrated load was largest of all, and that at the apex of implant was least of all, and the amount
of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all,
and that at the apex of implant was least of all.
2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased
according to the reference points. But the order according to the amount of total deflection
was not changed except apex of second premolar and central fossa of implant abutment under concentrated
load during distal inclination.
3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated
load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the
distal margin of second premolar under distributed load was largest of all, and that at the apex of
implant was least of all.
4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant
were increased under concentrated load and distributed load, but those were increased remarkably
under distributed load and so that at 30° mesial inclination was largest of all.
5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant
were increased remarkably under concentrated load and distributed load, and so those at 30° distal
inclination were largest of all.
목차
서 론
연구 재료 및 방법
연구 성적
총괄 및 고안
결 론
참고문헌
키워드
해당간행물 수록 논문
- 부분 무치악에서의 Osseointegrated Implant에 관안 고찰
- 치과임플랜트 매식후 조기기능이 임플랜트 주위골조직에 미치는 영향에 관한 연구
- 다발성 하악 골절시 자가골이식과 골내 임플란트를 이용한 수복술
- 치과 임플랜트 보철 수복시 각 상부구조의 형태에 따라 발생되는 응력의 광탄성학적 분석
- 齒科 임플랜트 補綴의 審美的 修復 方法에 따른 應力分析의 有限 要素法的 研究
- 골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석
- 권 두 언
- 치과 임플랜트 시술시 골천공기구의 회전속도가 주위 골조직의 온도 및 골일체성에 미치는 영향에 관한 연구
- 유한요소분석법을 이용한 치근형 임플랜트의 응력분포에 관한 연구
- 성견에서 발치 직후 Titanium plasma sprayed IMZ 임프란트 이식시 조직유도 재생술에 따른 골 재생력에 관한 연구
- 고정성 보철물을 지지하는 골유착성 임풀란트의 위치에 따른 지지조직에서의 유한요소적 응력분석
- 고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구
참고문헌
관련논문
의약학 > 의학일반분야 BEST
- 교육전담간호사가 주도하는 임상현장교육 프로그램이 신규 간호사의 간호업무성과와 교육 만족도에 미치는 효과
- 일반인을 위한 해부학 만화
- 중환자실 간호사의 간호근무환경과 직무 스트레스가 간호업무성과에 미치는 영향
의약학 > 의학일반분야 NEW
- 안구내용적출 시 자가통증조절장치를 이용한 선제적 전신 진통제의 효과
- 빅데이터를 이용한 COVID-19 백신 접종 후 발생한 안과적 이상사례에 대한 고찰
- 만성 중심장액맥락망막병증에서 국소레이저광응고술과 유리체 내 베바시주맙 주입술의 효과 비교
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!