국문 초록

영문 초록

In order to investigate the influence of functional stress on the tissue reaction around the implants, the tissues around functional, and non-functional endosseous titanium blade-vent implants were observed histologically for up to one year postoperatively. The mandibular left 2nd, 3rd premolar teeth in 4 healthy dogs (about 40 kg B.W.) were removed. Twelve weeks after extraction, titanium implants were implanted into the extracted area. Two implants which had smaller posts compared with natural teeth were implanted very deeply, not to be functional, into the mandibles of the dogs. But the other two implants had relatively large posts, and these were implanted so as to receive functional stress. One year after the implantation the tissue blocks containing the implants were removed. These block sections were fixed in 10% neutral buffered formalin for 2 days and decalcified in 15% formic acid. The buccal side of the blocks were removed with the knife and the implants were detached to the buccal side. The tissue blocks were embedded by paraffin embedding method and then sectioned by 7 /Jim. They were stained with hematoxylin and eosin. The obtained results were as follows. 1. Two layers of fibrous capsule existed around the functional implants. Collagen fibers of the implant-side layer were parallel with the implant surface, and perpendicular or irregular in the bone-side layer. 2. No fibrous capsule was observed around the non-functional implants. The osseous tissue interfaced with titanium was normal compact bone. In this study, existence of fibrous capsule was suggested to have correlation with functional stress.

목차

서 론
재료 및 방법
결 과
고 찰
결 론
REFERENCE

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

최목균,배창,박금수. (1985).기능적 긴장이 Endosseous Titanium Implant 주위의 결체조직성 피막형성에 미치는 영향. Journal of Dental Implant Research, 6 (1), 65-71

MLA

최목균,배창,박금수. "기능적 긴장이 Endosseous Titanium Implant 주위의 결체조직성 피막형성에 미치는 영향." Journal of Dental Implant Research, 6.1(1985): 65-71

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제