본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

B형 간염 표면 항체 역가 검사의 시약 간 비교분석

이용수 2

영문명
Comparative Analysis between Reagents for Hepatitis B Surface Antibody Titer Test
발행기관
대한핵의학기술학회
저자명
정세희(Se-Hee Jeong) 이영지(Yung-Ji Lee) 이선호(Sun-Ho Lee)
간행물 정보
『핵의학기술』Vol.28 No.2, 143~151쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2024.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: It is important for liver transplant patients to maintain a certain level of hepatitis B antibodies to prevent recurrence of hepatitis B after liver transplant surgery. The liver transplant and hepatobiliary surgery department at our hospital uses hepatitis B surface antibody titer testing as an important indicator in monitoring liver transplant patients. Recently, our hospital switched to reagents from company B due to an unstable supply of reagents and consumables from company A. Therefore, we evaluated the differences and correlation between those two reagents. Materials and Methods: A reagent comparison experiment between Company A and Company B was conducted on 69 samples of the hepatitis B surface antibody test requested in April 2022. Company A's reagent is a two-step test using beads, and Company B's reagent is a one-step test using a tube. For comparative experiments, samples diluted 10 times with stock solution and physiological saline were used, and the correlation between these reagents was analyzed by dilution factor. Results: The correlation graph between the two reagents shows the gradual upward gradient, and the result of B's reagent tended to be 5 times lower than A's reagent. The correlation between the 10-fold dilution of B's reagent, which is multiplied by 5, and the 10-fold dilution of A's reagent was compared for a similar value of A's reagent. Consequently, that was y = 1.1426x - 145.44, R² = 0.9828, which means a good correlation with an increased gradient. Furthermore, the B took 90 minutes to react, though the A took more than 120 minutes to test. Conclusion: Overall, B's reagent showed a lower value approximately 5 times rather than A's reagent, and there is the most valuable correlation between the 10-fold dilution of A's reagent and the 10-fold dilution of B's reagent multiplied by 5. If the 5-fold corrected value is referred to when reporting results using B's reagent, antibody trend analysis will be possible, similar to the result of the previous reagent. Also, it leads to an improvement in the laboratory's work efficiency significantly by the shorter test time.

영문 초록

목차

서론
대상 및 방법
결과
고찰
결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정세희(Se-Hee Jeong),이영지(Yung-Ji Lee),이선호(Sun-Ho Lee). (2024).B형 간염 표면 항체 역가 검사의 시약 간 비교분석. 핵의학기술, 28 (2), 143-151

MLA

정세희(Se-Hee Jeong),이영지(Yung-Ji Lee),이선호(Sun-Ho Lee). "B형 간염 표면 항체 역가 검사의 시약 간 비교분석." 핵의학기술, 28.2(2024): 143-151

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제