본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

방사면역 측정법에 의한 25-OH-VitD와 25-OH-VitD3의 비교 평가

이용수 0

영문명
Comparative Evaluation of 25-OH-VitD and 25-OH-VitD3 by Radioimmunoassay
발행기관
대한핵의학기술학회
저자명
이영지(Young-ji Lee) 박지혜(Ji-hye Park) 임수연(Soo-yeon Lim) 천준홍(Jun-hong Cheon) 이선호(Sun-ho Lee)
간행물 정보
『핵의학기술』Vol.24 No.1, 33~38쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2020.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Vitamin D is essential for maintaining bone health, controling cell proliferation or differentiation, strengthening immune function by controlling calcium metabolism in the body. Vitamin D deficiency can lead to increase the risk of rickets, osteoporosis, cardiovascular disease, diabetes and cancer. Especially, South Korea is one of the highest population proportion of vitamin D deficiency. Accurate determination of levels of 25-OH-VitD or 25-OH-VitD3 in blood serum is required for the diagnosis and treatment of vitamin D deficiency. In this study, radioimmunoassay of 25-OH-VitD and 25-OH-VitD3 was performed and compared to evaluate the effectiveness of Vitamin D radioimmunoassay. Materials and Methods Serum 25-OH-VitD and 25-OH-VitD3 levels were measured using radioimmunoassay. The interrelationship, reproducibility and population distribution rate were evaluated. In addition, the internal quality control was performed at Asan Medical Center from April 2017 to June 2019 and the result of external quality control (Interagency proficiency evaluation) of first and second half of 2018 hosted by the Korean Society of Nuclear Medicine Technology (KSNMT). Both tests were measured by same manufacturer's reagent. Results 25-OH-VitD showed a strong positive correlation on 97 samples, as 25-OH-VitD3 x 0.9 + 0.3 (R >0.9). In repeated measurement, the average Diff(%) value of the reproducibility evaluation of 25-OH-VitD and 25-OH-VitD3 were 7.7% and 7.4%, respectively. Population distribution results showed no statistically significant differences(p>0.05). The resultant value of internal quality control, which measured from April, 2017 to June 2019 in Blood test room of Nuclear Medicine at Asan Medical Center, showed average (CV%) 6.2% and 6.8%, respectively. As a result of the external quality control (interagency proficiency evaluation) Z value obtained under 2.0, as shown below; Conclusion The interrelationship, reproducibility, population distribution rate, internal quality control and external quality control between 25-OH-VitD and 25-OH-VitD3 radioimmunoassay shows superior outcome. Radioimmunoassay, which can be alone measured in the blood as 25-OH-VitD or 25-OH-VitD3, is considered suitable screening tests for the diagnosis of vitamin D deficiency.

목차

서 론
실험재료 및 방법
결 과
고 찰
결 론
요 약
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이영지(Young-ji Lee),박지혜(Ji-hye Park),임수연(Soo-yeon Lim),천준홍(Jun-hong Cheon),이선호(Sun-ho Lee). (2020).방사면역 측정법에 의한 25-OH-VitD와 25-OH-VitD3의 비교 평가. 핵의학기술, 24 (1), 33-38

MLA

이영지(Young-ji Lee),박지혜(Ji-hye Park),임수연(Soo-yeon Lim),천준홍(Jun-hong Cheon),이선호(Sun-ho Lee). "방사면역 측정법에 의한 25-OH-VitD와 25-OH-VitD3의 비교 평가." 핵의학기술, 24.1(2020): 33-38

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제