학술논문
핵의학 투고 논문 분류 및 방향성 고찰
이용수 0
- 영문명
- Classification of submitted nuclear medicine dissertation and directional consideration
- 발행기관
- 대한핵의학기술학회
- 저자명
- 조호연(Ho-Yeon Cho) 우영란(Yeong-Ran Woo) 서강록(Kang-Rok Seo) 홍건철(Gun-Chul Hong)
- 간행물 정보
- 『핵의학기술』Vol.26 No.2, 37~42쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2022.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period.
Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared.
Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM.
Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.
목차
서 론
실험재료 및 방법
결 과
고찰 및 결론
Reference
해당간행물 수록 논문
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!