본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup

이용수 0

영문명
Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup
발행기관
대한방사선종양학회
저자명
Jaeha Lee Yeon Joo Kim Youngmoon Goh Eunyeong Yang Ha Un Kim Si Yeol Song Young Seok Kim
간행물 정보
『대한방사선종양학회지』제41권 제3호, 172~177쪽, 전체 6쪽
주제분류
의약학 > 종양학
파일형태
PDF
발행일자
2023.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Surface-guided radiation therapy is an image-guided method using optical surface imaging that has recently been adopted for patient setup and motion monitoring during treatment. We aimed to determine whether the surface guide setup is accurate and efficient compared to the skin-marking guide in prostate cancer treatment. Materials and Methods: The skin-marking setup was performed, and vertical, longitudinal, and lateral couch values (labeled as “M”) were recorded. Subsequently, the surface-guided setup was conducted, and couch values (labeled as “S”) were recorded. After performing cone-beam computed tomography (CBCT), the final couch values was recorded (labeled as “C”), and the shift value was calculated (labeled as “Gap (M-S),” “Gap (M-C),” “Gap (S-C)”) and then compared. Additionally, the setup times for the skin marking and surface guides were also compared. Results: One hundred and twenty-five patients were analyzed, totaling 2,735 treatment fractions. Gap (M-S) showed minimal differences in the vertical, longitudinal, and lateral averages (-0.03 cm, 0.07 cm, and 0.06 cm, respectively). Gap (M-C) and Gap (S-C) exhibited a mean difference of 0.04 cm (p = 0.03) in the vertical direction, a mean difference of 0.35 cm (p = 0.52) in the longitudinal direction, and a mean difference of 0.11 cm (p = 0.91) in the lateral direction. There was no correlation between shift values and patient characteristics. The average setup time of the skin-marking guide was 6.72 minutes, and 7.53 minutes for the surface guide. Conclusion: There was no statistically significant difference between the surface and skin-marking guides regarding final CBCT shift values and no correlation between translational shift values and patient characteristics. We also observed minimal difference in setup time between the two methods. Therefore, the surface guide can be considered an accurate and time-efficient alternative to skin-marking guides.

목차

Introduction
Materials and Methods
Results
Discussion and Conclusion
Statement of Ethics
Conflict of Interest
Funding
Author Contributions
Data Availability Statement
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Jaeha Lee,Yeon Joo Kim,Youngmoon Goh,Eunyeong Yang,Ha Un Kim,Si Yeol Song,Young Seok Kim. (2023).Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup. 대한방사선종양학회지, 41 (3), 172-177

MLA

Jaeha Lee,Yeon Joo Kim,Youngmoon Goh,Eunyeong Yang,Ha Un Kim,Si Yeol Song,Young Seok Kim. "Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup." 대한방사선종양학회지, 41.3(2023): 172-177

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제