학술논문
접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가
이용수 64
- 영문명
- Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process
- 발행기관
- 한국환경보건학회
- 저자명
- 우재민(Jaemin Woo) 김동준(Dongjun Kim) 신지훈(Jihun Shin) 민기홍(Gihong Min) 이채관(Chaekwan Lee) 양원호(Wonho Yang)
- 간행물 정보
- 『1. 한국환경보건학회지』제49권 제2호, 78~88쪽, 전체 11쪽
- 주제분류
- 공학 > 환경공학
- 파일형태
- 발행일자
- 2023.04.30
4,120원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces.
Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments.
Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace.
Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1.
However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected.
Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.
목차
해당간행물 수록 논문
- 인체 간세포주 HepG2 및 발광박테리아를 활용한 유기인계 난연제와 그 혼합물의 독성 스크리닝
- 랫드에서 Aldehyde Dehydrogenase Related Compounds의 알콜 및 알데히드 분해 효능평가
- 청소년의 궐련형 전자담배 현재 사용에 따른 관련 요인 분석
- 울산 산단지역 PM2.5 중 중금속 노출에 의한 건강위해성평가
- 극저주파 자기장의 소아백혈병 발생 위험 고찰
- 접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가
- 타투화장품 및 문신용 염료의 유해금속 함량 연구
- [편집인의 글] 지하역사 내 초미세먼지 농도 저감 방안에 대하여
- 한국환경보건학회지 제49권 제2호 목차
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!