A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography

이용수 2

영문명
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
김은혜(Eun-Hye Kim) 박혜민(Hye-Min Park) 김정민(Jung-Min Kim)
간행물 정보
『방사선기술과학』방사선기술과학 제45권 제2호, 127~134쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2022.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

목차

Ⅰ. Introduction
Ⅱ. Materials and Methods
Ⅲ. Results and Discussion
Ⅳ. Conclusion
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김은혜(Eun-Hye Kim),박혜민(Hye-Min Park),김정민(Jung-Min Kim). (2022).A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography. 방사선기술과학, 45 (2), 127-134

MLA

김은혜(Eun-Hye Kim),박혜민(Hye-Min Park),김정민(Jung-Min Kim). "A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography." 방사선기술과학, 45.2(2022): 127-134

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제