학술논문
A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector
이용수 51
- 영문명
- 발행기관
- 한국방사선학회
- 저자명
- Yung-Kyoon Kim Dong-Kyoon Han
- 간행물 정보
- 『한국방사선학회 논문지』 제16권 제1호, 67~74쪽, 전체 8쪽
- 주제분류
- 공학 > 기타공학
- 파일형태
- 발행일자
- 2022.02.28
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09∼11.99%, 4.12∼35.52%, and 4.70∼ 37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.
목차
Ⅰ. INTRODUCTION
Ⅱ. MATERIAL AND METHODS
Ⅲ. RESULT
Ⅳ. DISCUSSION
Ⅴ. CONCLUSION
해당간행물 수록 논문
- Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source
- A Study on Radiation Dose and Image Quality using Dual Energy Computed Tomography ECG Gating High Pitch Chest Pain Protocol Mode
- Analysis of Photon Spectrum for the use of Added Filters using 3D Printing Materials
- A Study on Satisfaction with Online Classes of Radiology Students due to COVID-19
- Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes
- A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector
- Performance Evaluation of YOLOv5s for Brain Hemorrhage Detection Using Computed Tomography Images
- 한국방사선학회 논문지 제16권 제1호 목차
- Comparisons of Image Quality and Entrance Surface Doses according to Care Dose 4D + Care kV in Chest CT
- Evaluation of Artificial Intelligence Accuracy by Increasing the CNN Hidden Layers: Using Cerebral Hemorrhage CT Data
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!