본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

정조 상태에서 백미에 대한 완전미율의 비파괴 예측

이용수 0

영문명
Non-Destructive Prediction of Head Rice Ratios using NIR Spectra of Hulled Rice
발행기관
한국작물학회
저자명
권영립(Young-Rip Kwon) 조승현(Seung-Hyun Cho) 이재흥(Jae-Heung Lee) 서경원(Kyoung-Won Seo) 최동칠(Dong-Chil Choi)
간행물 정보
『한국작물학회지』제53권 제3호, 244~250쪽, 전체 7쪽
주제분류
농수해양 > 기타농수해양
파일형태
PDF
발행일자
2008.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The purpose of this study was to measure fundamental data required for the prediction of milling ratios, and to develop regression models to predict the head rice ratio of milled rice using NIR spectra of hulled rice. A total of 81 rice samples used in this study were collected from Jeongeup, Jeonbuk province in 2006. NIR spectra were measured using one mode of measurement, reflection. The reflectance spectra were measured in the wavelength region of 400-2500 nm with an NIR spectrophotometer “NIRSystems 6500” (Foss, Silverspring, USA). Calibration equations were developed by the modified partial least squares (MPLS), partial least squares (PLS), and principal components regres-sion (PCR). Math treatments were 1-4-4-1, 1-10-10-1, 2-4-4-1, and 2-10-10-1. The software used was WinISI (In-frasoft International, State College, USA). Automatic head rice production and quality checking system used was “SY2000-AHRPQCS” (Ssangyong, Korea). The calibration was made with the first derivative and the spectrum designated was in 8 nm interval. The determination coeffi-cients of head rice ratios were 0.8353, 0.8416 and 0.5277 for the MPLS, PLS and PCR, respectively. Those obtained with 20 nm interval were 0.8144, 0.8354 and 0.6908 for the MPLS, PLS and PCR, respectively. The calibration was made with second derivative that spectrum designated was 8 nm in interval. The determination coefficients of head rice ratios were 0.7994, 0.8017 and 0.4473 for the MPLS, PLS and PCR, respectively. Those with 20 nm interval were 0.8004, 0.8493 and 0.6609 for the MPLS, PLS and PCR, respectively. These results indicate that the accuracy of determination coefficient for MPLS and PLS is higher than that of PCR.

목차

재료 및 방법
결과 및 고찰
적요
인용문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

권영립(Young-Rip Kwon),조승현(Seung-Hyun Cho),이재흥(Jae-Heung Lee),서경원(Kyoung-Won Seo),최동칠(Dong-Chil Choi). (2008).정조 상태에서 백미에 대한 완전미율의 비파괴 예측. 한국작물학회지, 53 (3), 244-250

MLA

권영립(Young-Rip Kwon),조승현(Seung-Hyun Cho),이재흥(Jae-Heung Lee),서경원(Kyoung-Won Seo),최동칠(Dong-Chil Choi). "정조 상태에서 백미에 대한 완전미율의 비파괴 예측." 한국작물학회지, 53.3(2008): 244-250

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제