본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가

이용수 6

영문명
Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
정홍량(Hong-Ryang Jung)
간행물 정보
『방사선기술과학』방사선기술과학 제44권 제5호, 435~441쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2021.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 ㎠). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 ㎠. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver’s method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver’s method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver’s method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver’s method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver’s method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver’s method. This was found to be statistically significant( p<0.000).

목차

Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정홍량(Hong-Ryang Jung). (2021).유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가. 방사선기술과학, 44 (5), 435-441

MLA

정홍량(Hong-Ryang Jung). "유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가." 방사선기술과학, 44.5(2021): 435-441

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제