학술논문
새로운 발 사방향 검사법의 유용성에 관한 연구
이용수 12
- 영문명
- A Study on the Usefulness of the New Foot Oblique Projection
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 김민석(Min-Suk Kim) 주영철(Young-Cheol Joo) 이승근(Seung-Keun Lee)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제44권 제5호, 443~449쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2021.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28 ∼9.56 mm. The qualitative evaluation showed a reliability of 0.95∼1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°∼60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.
목차
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
키워드
해당간행물 수록 논문
- 방사선검사의 의무기록에 관한 요구도 분석
- 몬테카를로 시뮬레이션 기반 밀도에 따른 다양한 검출기 물질을 적용한 획득 영상 평가
- 다층구조 엑스선 검출기를 이용한 이중에너지 조영제 영상의 물질 구분에 관한 연구
- 담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가
- ²⁰¹Tl의 생산과정에서 발생한 방사성 폐기물의 제염 효율 평가
- 방사선사법 제정 위한 미국 전문 방사선사 면허제도 고찰
- 방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도
- 새로운 발 사방향 검사법의 유용성에 관한 연구
- 의료기사 등에 관한 법률에서 ‘의사 또는 치과의사의 지도’ 문구에 대한 법률 개정 요구도
- Comparison of Based on Histogram Equalization Techniques by Using Normalization in Thoracic Computed Tomography
- 한국 노인의 일반촬영 이용량 및 피폭선량
- 인터벤션시술 진단참고수준 평가
- 의료기사 등에 관한 법률 중 ‘의사 또는 치과의사의 지도 아래’ 문구의 타당성에 대한 고찰
- 유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가
- 방사선사법 제정의 필요성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!