본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

새로운 발 사방향 검사법의 유용성에 관한 연구

이용수 12

영문명
A Study on the Usefulness of the New Foot Oblique Projection
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
김민석(Min-Suk Kim) 주영철(Young-Cheol Joo) 이승근(Seung-Keun Lee)
간행물 정보
『방사선기술과학』방사선기술과학 제44권 제5호, 443~449쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2021.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28 ∼9.56 mm. The qualitative evaluation showed a reliability of 0.95∼1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°∼60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

목차

Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김민석(Min-Suk Kim),주영철(Young-Cheol Joo),이승근(Seung-Keun Lee). (2021).새로운 발 사방향 검사법의 유용성에 관한 연구. 방사선기술과학, 44 (5), 443-449

MLA

김민석(Min-Suk Kim),주영철(Young-Cheol Joo),이승근(Seung-Keun Lee). "새로운 발 사방향 검사법의 유용성에 관한 연구." 방사선기술과학, 44.5(2021): 443-449

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제