본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사

이용수 52

영문명
The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation
발행기관
한국환경보건학회
저자명
전정인(Jeong-In Joen) 이혜원(Hye-Won Lee) 최현진(Hyun-Jin Choi) 전형진(Hyung-Jin Jeon) 이철민(Cheolmin Lee)
간행물 정보
『1. 한국환경보건학회지』제47권 제5호, 398~409쪽, 전체 12쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2021.10.31
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM₁₀ in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO₂ in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

목차

I. 서 론
II. 연구 방법
III. 결 과
IV. 고 찰
V. 결 론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

전정인(Jeong-In Joen),이혜원(Hye-Won Lee),최현진(Hyun-Jin Choi),전형진(Hyung-Jin Jeon),이철민(Cheolmin Lee). (2021).다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사. 1. 한국환경보건학회지, 47 (5), 398-409

MLA

전정인(Jeong-In Joen),이혜원(Hye-Won Lee),최현진(Hyun-Jin Choi),전형진(Hyung-Jin Jeon),이철민(Cheolmin Lee). "다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사." 1. 한국환경보건학회지, 47.5(2021): 398-409

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제