광주지역 바닥분수의 수질특성 평가

이용수 6

영문명
Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju
발행기관
한국환경보건학회
저자명
김종민(Jong-Min Kim) 김하람(Ha-Ram Kim) 장서은(Seo-Eun Jang) 최영섭(Yeong-Seop Choi) 강유미(Yu-Mi Kang) 정숙경(Sook-Kyoung Jung) 조영관(Young-Gwan Cho) 김은선(Eun-Sun Kim)
간행물 정보
『1. 한국환경보건학회지』제43권 제2호, 143~156쪽, 전체 14쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2017.04.30
4,480

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

목차

1. 서 론
II. 이론적 배경
III. 재료 및 방법
IV. 결과 및 고찰
V. 결 론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김종민(Jong-Min Kim),김하람(Ha-Ram Kim),장서은(Seo-Eun Jang),최영섭(Yeong-Seop Choi),강유미(Yu-Mi Kang),정숙경(Sook-Kyoung Jung),조영관(Young-Gwan Cho),김은선(Eun-Sun Kim). (2017).광주지역 바닥분수의 수질특성 평가. 1. 한국환경보건학회지, 43 (2), 143-156

MLA

김종민(Jong-Min Kim),김하람(Ha-Ram Kim),장서은(Seo-Eun Jang),최영섭(Yeong-Seop Choi),강유미(Yu-Mi Kang),정숙경(Sook-Kyoung Jung),조영관(Young-Gwan Cho),김은선(Eun-Sun Kim). "광주지역 바닥분수의 수질특성 평가." 1. 한국환경보건학회지, 43.2(2017): 143-156

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제