자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향

이용수 20

영문명
Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
정운찬(Jeong Woon-Chan) 주영철(Joo Young-Cheol)
간행물 정보
『방사선기술과학』방사선기술과학 제44권 제2호, 85~90쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2021.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom’s lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, ㎃s, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 ㎝ and 8 ㎝ back and forth and compared dose factors and image quality. The exposure parameters were 85 ㎸p, 320 ㎃, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 ㎝. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 m㏉, without AEC was 2.12±0.01 m㏉. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom’s center moves 4 ㎝, 8 ㎝ forward, and 4 ㎝, 8 ㎝ backward, ESD were 1.09±0.004 m㏉, 0.32±0.003 m㏉, 1.19±0.017 m㏉, 1.11±0.006 m㏉ respectively, SNR were 18.29±0.60 ㏈, 11.11±0.22 ㏈, 18.98±0.80 ㏈, 17.71±0.82 ㏈. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and ㎃s by 38%, without any difference in SNR(p<0.05). When the phantom’s center moves 4 ㎝, 8 ㎝ forward, and 4 ㎝, 8 ㎝ backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

목차

Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정운찬(Jeong Woon-Chan),주영철(Joo Young-Cheol). (2021).자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향. 방사선기술과학, 44 (2), 85-90

MLA

정운찬(Jeong Woon-Chan),주영철(Joo Young-Cheol). "자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향." 방사선기술과학, 44.2(2021): 85-90

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제