본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

복부 방사선검사 자세가 유방선량에 미치는 영향

이용수 30

영문명
Effects of Breast Dose on Plain Abdominal Position
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
주영철(Joo Young-Cheol) 김승혁(Kim Sheung-Hyuk)
간행물 정보
『방사선기술과학』방사선기술과학 제43권 제3호, 155~159쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2020.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 ㎸p, 320 ㎃, 50 ㎳, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μ㏉ and 414.46±33.52 μ㏉ for erect AP, and 145.80±18.52 μ㏉ and 148.76±12.92 μ㏉ in erect PA. The superficial breast dose was 754.00±68.36 μ㏉ on the medial side and 674.06±45.58 μ㏉ on the lateral side in the erect AP, 70.66±7.98 μ㏉ on the medial side, and 86.46±15.35 μ㏉ on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

목차

Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

주영철(Joo Young-Cheol),김승혁(Kim Sheung-Hyuk). (2020).복부 방사선검사 자세가 유방선량에 미치는 영향. 방사선기술과학, 43 (3), 155-159

MLA

주영철(Joo Young-Cheol),김승혁(Kim Sheung-Hyuk). "복부 방사선검사 자세가 유방선량에 미치는 영향." 방사선기술과학, 43.3(2020): 155-159

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제