본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

이용수 0

영문명
발행기관
한국전문물리치료학회
저자명
Hye-jin Min Tae-lim Yoon
간행물 정보
『한국전문물리치료학회지』한국전문물리치료학회지 제26권 제3호, 76~83쪽, 전체 8쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2019.08.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen’s kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

목차

Introduction
Methods
Results
Discussion
Conclusion

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Hye-jin Min,Tae-lim Yoon. (2019).Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests. 한국전문물리치료학회지, 26 (3), 76-83

MLA

Hye-jin Min,Tae-lim Yoon. "Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests." 한국전문물리치료학회지, 26.3(2019): 76-83

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제