본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

이용수 0

영문명
발행기관
대한안과학회
저자명
Joong Won Shin Yong Un Shin Hee Yoon Cho Byung Ro Lee
간행물 정보
『The Korean Journal of Ophthalmology』Vol.26 No.4, 255~259쪽, 전체 5쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2012.08.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To study choroidal thickness and its topographic profile in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography and the correlation with age and refractive error. Methods: Fifty-seven eyes (45 individuals) with no visual complaints or ocular disease underwent horizontal and vertical line scanning using 3D OCT-1000. The definition of choroidal thickness was the vertical distance between the posterior edge of the hyper-reflective retinal pigment epithelium and the choroid/sclera junction. Choroidal thickness was measured in the subfoveal area at 500 μm intervals from the fovea to 2,500 μm in the nasal, temporal, superior, and inferior regions. The spherical equivalent refractive error was measured by autorefractometry. Statistical analysis was used to confirm the correlations of choroidal thickness with age and refraction error. Results: The mean age of the 45 participants (57 eyes) was 45.28 years. Detailed visualization of the choroid for measuring its thickness was possible in 63.3% of eyes. The mean subfoveal choroidal thickness was found to be 270.8 μm (standard deviation [SD], ±51 μm), in horizontal scanning and 275.0 μm (SD, ±49 μm) in vertical scanning. The temporal choroidal thickness was greater than any 500 μm interval in corresponding locations, and there was no significant difference between the superior and inferior choroid as far as 2,000 μm from the fovea. Age and refractive error were associated with subfoveal choroidal thickness in terms of regression (p < 0.05). Conclusions: Choroidal thickness in normal Korean eyes can be measured using 3D OCT-1000 with high resolution line scanning. The topographical profile of choroidal thickness varies depending on its location. Age and refractive error are essential factors for interpretation of choroidal thickness.

목차

Materials and Methods
Results
Discussion
Conflict of Interest
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Joong Won Shin,Yong Un Shin,Hee Yoon Cho,Byung Ro Lee. (2012).Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography. The Korean Journal of Ophthalmology, 26 (4), 255-259

MLA

Joong Won Shin,Yong Un Shin,Hee Yoon Cho,Byung Ro Lee. "Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography." The Korean Journal of Ophthalmology, 26.4(2012): 255-259

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제