흉부 방사선검사에서 자동노출제어 사용에 관한 연구

이용수 49

영문명
A Study on the Using of Automatic Exposure Control in the Chest Radiography
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
최성식(Sung Sik Choi) 임청환(Cheong Hwan Lim) 정성훈(Sung Hoon Jung)
간행물 정보
『방사선기술과학』방사선기술과학 제42권 제1호, 19~24쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2019.02.28
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference( p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.

목차

Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

최성식(Sung Sik Choi),임청환(Cheong Hwan Lim),정성훈(Sung Hoon Jung). (2019).흉부 방사선검사에서 자동노출제어 사용에 관한 연구. 방사선기술과학, 42 (1), 19-24

MLA

최성식(Sung Sik Choi),임청환(Cheong Hwan Lim),정성훈(Sung Hoon Jung). "흉부 방사선검사에서 자동노출제어 사용에 관한 연구." 방사선기술과학, 42.1(2019): 19-24

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제