학술논문
접촉성 감염환자 흉부검사 시 의료관련감염 예방에 대한 연구
이용수 70
- 영문명
- A Study on the Prevention of Healthcare Associated Infection in Chest PA Projection of Contact Infected Patients
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 이상원(Sang-Won Lee) 김동진(Dong-Jin Kim) 이배원(Bae-Won Lee)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제41권 제4호, 297~304쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2018.08.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
This study proposes measures and methods to reduce healthcare associated infections by comparing and analyzing the bacterial contamination level before and after putting on personal protective equipment (PPE) on the test equip-ment and the contact infected patients getting chest PA projections. Among the 50 inpatients who were diagnosed with C. difficile, MRSA, and VRE, 28 patients who were instructed to undergo chest PA projection and follow-up were chosen, The 3 parts that come in contact with the detector, chin, chest, and hands, were designated for all, and the bacterial contamination level before and after disinfection and before and after putting PPE was determined. Statistical analysis was performed using Medcalc version 14, and quantitative analysis was performed using paired student t-test, with statistical significance being noted at p<0.05. Results for the comparison of the mean values before and after disinfection of the detector, chin (3.000), chest (2.000), and hands (3.430), showed that the number of bacteria after disinfection was lower than it was before disinfection. Analyzing for each part before and after disinfection, there were statistically significant differences for the chin, chest, and hands (p<0.01). Results for the comparison of the mean values before and after putting on PPE, chin (2.202), chest (2.140), and hands (4.213), showed that the number of bacteria after putting on PPE was lower than it was before putting on PPE. Analyzing for each part before and after putting on PPE, there were statistically significant differences for the chin, chest, and hands (p<0.03). As a result, it was confirmed that the number of bacteria after putting on PPE was lower than it was before putting it on. In the future, expanding the research scope for contact infected patients will establish standards for quarantine guidelines depending on the way it spreads, and contribute to the prevention of healthcare associated infections.
영문 초록
목차
Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
키워드
해당간행물 수록 논문
- 접촉성 감염환자 흉부검사 시 의료관련감염 예방에 대한 연구
- 일반인들의 항공여객기 이용 시 우주방사선 피폭선량 비교 분석
- 심장외막지방두께와 당뇨와의 연관성 연구
- 초음파골밀도측정기 정도관리 방안제시를 위한 한국 초음파골밀도 사용현황 조사
- 이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법
- 대사증후군과 하부요로증상, PSA 및 전립샘 용적과의 연관성 : 단일기관 연구
- PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가
- UAE로 취업한 한인 의료직 종사자의 임상 경험
- 이동형 방사선 차폐장치의 성능평가에 관한 연구
- 방사선 전공 대학생의 스마트폰 중독이 자기통제력에 미치는 영향 분석
- 방사선기술과학 제41권 제4호 목차
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!