이동형 방사선 차폐장치의 성능평가에 관한 연구

이용수 42

영문명
A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
구본열(Koo Bon-Yeoul) 한상현(Han Sang-Hyun)
간행물 정보
『방사선기술과학』방사선기술과학 제41권 제4호, 289~295쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2018.08.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every 30° from the head direction(-90°) to the body direction(+90°). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from 5.1±0.26 μ Gy to 7.1±0.15 μGy when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from 7.1±0.15 μGy to 0.7±0.07 μGy. The spatial dose of natural radiation was measured to be about 0.2±0.04 μGy when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

영문 초록

목차

Ⅰ. 서 론
Ⅱ. 연구 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

구본열(Koo Bon-Yeoul),한상현(Han Sang-Hyun). (2018).이동형 방사선 차폐장치의 성능평가에 관한 연구. 방사선기술과학, 41 (4), 289-295

MLA

구본열(Koo Bon-Yeoul),한상현(Han Sang-Hyun). "이동형 방사선 차폐장치의 성능평가에 관한 연구." 방사선기술과학, 41.4(2018): 289-295

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제