학술논문
CT실의 환경오염평가와 환경소독에 관한 연구
이용수 52
- 영문명
- The Estimation of Environmental Contamination and Environmental Disinfection in Computed Tomography Room
- 발행기관
- 대한CT영상기술학회
- 저자명
- 정재호(Jae HO Jung) 박명래(Myung Rae Park) 민강미(Kang Mi Min) 신진호(Jin Ho Shin) 육진(Jin Yook) 정경일(Kyung Il Jung) 김용환(Yong Hwan Kim) 서세옥(Se Ok Seo)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 105~112쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose
Technological advance in computed tomography(CT) have led to an increase in the number of patients that can be admitted daily. This increase has caused a rise in nasocomial infections. This research was investigated the disinfectant power of two solutions: 75% ethyl alcohol and a diluted NaOCI 4% solution.
Materials and methods
In the research 5 representative bacteria were found in the CT room. The five strains of bacteria are coagulase-negative staphylococci (CNS), methicillin-resistant coagulase-negative staphylococci (MRCNS), methicillin-resistant staphylococci aureus(MRSA) and staphylococci aureus(SA). Samples were acquired from 10 locations: the patient couch, control button, door handle in the both CT scan rooms and telephone and operator mouse in both operator rooms. Following the naked eye survey method of a blood agar plate, colonies were described as many(+++, 3 or more colonies) moderate(++, 2 colonies), and 1 colony was few(+). Counting was done by using Mini-tab version 15 statistical processing program.
Results
A lot of CNS was detected 6 of the 10 locations(60%) in the both CT scan rooms and operator rooms before disinfection. Results after disinfection with 75% ethyl alcohol were detected in just 1 location which was moderate(++) and the others were few(+) or no growth. The extinction rate of total colonies was 97.5% compared with before disinfection. Results after disinfection with the NaOCL 4% diluted solution were detected in 3 locations with CNS. However all locations were classified as few(+) and total colonies was just one. The disinfection rate of both solutions was similar at 97.5% for the 75% ethyl alcohol solution and 98% for the NaOCI 4% solution.
Conclusion
Failing to disinfect the CT rooms daily leads to growth of non-pathogenic bacteria. Although the disinfectant power of both solutions was similar, this study recommends the use of NaOCI 4% because it was much more efficient dian the 75% ethyl alcohol.
목차
Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
- Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구
- Lumbar Spine Disease 환자의 2D Sagittal Reformation 시 Reformation Angle에 따른 Intervertebral Foramina Image에 대한 고찰
- CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구
- Volume Rendering CT Image의 TACE Reference Data로서의 유용성
- ECG-gated Cardiac MDCT 검사에서 심장기능 평가를 위한 최적의 수축기말과 확장기말 Phase(%)에 관한 연구
- Multi-detector Computed Tomography에서 환자의 자세 변화에 따른 Esophageal Cancer 진단의 유용성
- CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가
- CT실의 환경오염평가와 환경소독에 관한 연구
- Multi-detector Computed Tomography를 이용한 Neck 검사에서 Automatic Exposure Control을 이용한 선량의 최적화
- 폐 소결절 환자를 대상으로 한 CT-guided Wire Marking Procedure에 대한 유용성 평가
- Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!