Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성

이용수 32

영문명
The Usefulness of Prospectively ECG Gated High-pitch Cardiac Scan for CT Coronary Angiography Using Dual Source CT
발행기관
대한CT영상기술학회
저자명
이대규(Dae Kyu Lee) 김문찬(Moon Chan Kim) 방성호(Sung Ho Bang) 한동균(Dong Kyoon Han)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 25~33쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose To evaluate the usefulness of prospectively ECG gated high-pitch cardiac scan for CT coronary angiography(CTCA) using dual source CT by analyzing the dose effect and image quality for CTCA protocols. Materials and methods CTCA was performed by using 5 current clinical protocols to evaluate effective dose and organ dose in prima1y beam area with anthropomorphic female phantom and glass dosimetric system. Also, ACR phantom was used to analyze image quality at 128 channel multi-detector CT (scan parameters: 320 mAs at 120 kVp, collimation: 128 × 0.6 mm, scan range :137 mm, reconstructed slice thickness 0.6 mm, increment 0.4 mm). Heart beat rate of phantom was maintained 60 bpm in ECG gating. In a retrospectively ECG gated helical scan mode was done with 280 msecgantry rotation time, 0.23 pitch. Peak dose was used without cardiac dose modulation (pulsing off mode). Peak dose was adopted in range of 60%~80% of R-R interval and 25% reduction in others with cardiac dose modulation (pulsing manual mode). And peak dose was adopted in range of 60%~80% of R-R interval and 4% reduction in others with cardiac dose modulation (pulsing MinDose-manual mode). In a prospectively ECG gated sequential scan mode data were acquired at 70% R-R interval (middle diastolic phase in cardiac cycle), and 170 msec gantry rotation time was used. In a prospectively ECG gated high-pitch cardiac scan mode data were acquired from 60% R-R interval, and 3.4 pitch was used. Analysis of image quality was clone by evaluating objective noise, uniformity, high contrast resolution, and linearity. Results The mean effective dose for pulsing off mode without cardiac dose modulation in a retrospectively ECG gated helical scan was 20.8 mSv, and die mean organ dose of heart was 116.7 mGy. Pulsing manual mode showed 49% reduction, compared with that of pulsing off mode. And pulsing MinDose-manual mode showed 60% reduction compared with that of pulsing off mode. And at die adaptive sequential scan mode under prospective ECG gating die mean effective dose was 2.7 mSv, and die mean organ dose of heart was 17.5 mGy, d1is represents an 86% reduction compared with that of pulsing off mode. In the high pitch cardiac scan under prospective ECG gating die mean effective dose was 1.8 mSv, and the mean organ dose of heart was 10.3 mGy, this represents an 91% reduction compared with that of pulsing off mode. No differences in quantitative measures of linage quality were found between high pitch cardiac scan mode and others for noise, uniformity, high contrast resolution, linearity. Conclusion In patients with a low and stable heart rate, prospectively ECG gated high-pitch cardiac scan provides excellent image quality equivalent to retrospectively ECG gated helical scan-corelated acquisition but reduced effective dose.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이대규(Dae Kyu Lee),김문찬(Moon Chan Kim),방성호(Sung Ho Bang),한동균(Dong Kyoon Han). (2010).Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성. 대한CT영상기술학회지, 12 (1), 25-33

MLA

이대규(Dae Kyu Lee),김문찬(Moon Chan Kim),방성호(Sung Ho Bang),한동균(Dong Kyoon Han). "Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성." 대한CT영상기술학회지, 12.1(2010): 25-33

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제