CT검사시 목적장기 이외 부위의 차폐를 통한 피폭선량감소 효과에 관한 연구

이용수 124

영문명
Dose Reduction Effect with Shielding of Superficial Radiosensitive Organs of Out-plane in CT Examination
발행기관
대한CT영상기술학회
저자명
이홍(Hong Lee) 김문찬(Moon Chan Kim) 신상보(Sang Bo Shin)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제11권 제1호, 134~140쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose The study was done to evaluate radiation dose reduction effect through shielding like scattering ray to superficial radiosensitive organs which are adjacent to scanning field when head & neck, chest & abdomen CT examination. Materials and methods LightSpeed VCT(General Electric medical system, Milwaukee, USA) was used as CT equipment and Rando phantom(model RAN-110, Churchin associate LTD., USA) and glass dosimetry system(GD-351, 8.5mm, FGD-1000) in the measurement of radiation dose. There were two kinds of materials to shield from radiation, a lead apron(0.5mm Pb at 80kVp) was used in out-plane and bismuth(F & L medical products co.) was used in in-plane. The measurement of organs was divided into brain, neck, chest and abdomen. Scan protocol was as follow: 1. In the brain examination, 120kVp and dose modulation(1sec, min. 150~max. 250mA, noise index: 2.80) was used for the examination. The glass dosimetry elements were put on left and right lens of phantom eyeball(thyroid), and the radiation dose without and with the use bismuth(Pb) shield were measured three times. 2. In the neck examination, 120kVp and dose modulation(0.6sec, min. 150~max. 300mA, noise index: 6.0) was used for the examination. The glass dosimetry elements were put on left and right lens of phantom eyeball(the both nipples), and the radiation dose without and with the use bismuth(Pb) shield were measured three times. 3. In the chest examination, 120kVp, dose modulation(0.6sec, min. 100~max. 230mA, noise index: 15.86) was used of the pre-contrast and 120kVp, dose modulation(0.6sec, min. 100~max. 275mA, noise index: 15.86) was used of the post-contrast. The glass dosimetry elements were put on left and right phantom thyroid(umbilicus), and the radiation dose without and with the use bismuth(Pb) shield were measured three times. 4. In the abdomen examination, 120kVp and dose modulation(0.6sec, min. 100~max. 300mA, noise index: 11.57) used for examination. The glass dosimetry elements were put on the both nipples of phantom breast(gonad), and the radiation dose without and with bismuth shield were measured three times. Results 1. In brain CT scanning, shielding with bismuth of lens of eyeballs decreased the radiation dose about 46%(without: 43.98mGy, with: 23.86mGy) and shielding with Pb of thyroid decreased the radiation dose about 24%(without: 1.21mGy, with: 0.92mGy). 2. In neck CT scanning, shielding with bismuth of lens of eyeballs decreased the radiation dose about 42%(without: 66.47mGy, with: 38.58mGy) and shielding with Pb of breast decreased the radiation dose about 65%(without: 2.43mGy, with: 0.86mGy). 3. In chest CT scanning, shielding with bismuth of thyroid decreased the radiation dose about 22%(without: 20.74mGy, with: 16.1mGy) and shielding with Pb of umbilicus decreased the radiation dose about 44%(without: 1.34mGy, with: 0.75mGy). 4. In abdomen CT scanning, shielding with bismuth of breast decreased the radiation dose about 13%(without: 1.80mGy, with: 1.58mGy) and shielding with bismuth of gonad decreased the radiation dose about 33%(without: 23.08mGy, with: 15.46mGy). Conclusion According to the study, a percentage of the measured dose reduction is from min. 22% to max. 65%. The results have important meaning that there is much possibility of additional dose reduction through shielding not only in-plane but also out-plane. Consequently, the radiation dose given to patients can be decreased through the CT workers’ effort and concern like shielding out-plane from radiation.

목차

Abstract
Ⅰ. 목적
Ⅱ. 재료 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이홍(Hong Lee),김문찬(Moon Chan Kim),신상보(Sang Bo Shin). (2009).CT검사시 목적장기 이외 부위의 차폐를 통한 피폭선량감소 효과에 관한 연구. 대한CT영상기술학회지, 11 (1), 134-140

MLA

이홍(Hong Lee),김문찬(Moon Chan Kim),신상보(Sang Bo Shin). "CT검사시 목적장기 이외 부위의 차폐를 통한 피폭선량감소 효과에 관한 연구." 대한CT영상기술학회지, 11.1(2009): 134-140

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제