학술논문
CT검사시 목적장기 이외 부위의 차폐를 통한 피폭선량감소 효과에 관한 연구
이용수 124
- 영문명
- Dose Reduction Effect with Shielding of Superficial Radiosensitive Organs of Out-plane in CT Examination
- 발행기관
- 대한CT영상기술학회
- 저자명
- 이홍(Hong Lee) 김문찬(Moon Chan Kim) 신상보(Sang Bo Shin)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제11권 제1호, 134~140쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.09.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose
The study was done to evaluate radiation dose reduction effect through shielding like scattering ray to superficial radiosensitive organs which are adjacent to scanning field when head & neck, chest & abdomen CT examination.
Materials and methods
LightSpeed VCT(General Electric medical system, Milwaukee, USA) was used as CT equipment and Rando phantom(model RAN-110, Churchin associate LTD., USA) and glass dosimetry system(GD-351, 8.5mm, FGD-1000) in the measurement of radiation dose. There were two kinds of materials to shield from radiation, a lead apron(0.5mm Pb at 80kVp) was used in out-plane and bismuth(F & L medical products co.) was used in in-plane. The measurement of organs was divided into brain, neck, chest and abdomen. Scan protocol was as follow:
1. In the brain examination, 120kVp and dose modulation(1sec, min. 150~max. 250mA, noise index: 2.80) was used for the examination. The glass dosimetry elements were put on left and right lens of phantom eyeball(thyroid), and the radiation dose without and with the use bismuth(Pb) shield were measured three times.
2. In the neck examination, 120kVp and dose modulation(0.6sec, min. 150~max. 300mA, noise index: 6.0) was used for the examination. The glass dosimetry elements were put on left and right lens of phantom eyeball(the both nipples), and the radiation dose without and with the use bismuth(Pb) shield were measured three times.
3. In the chest examination, 120kVp, dose modulation(0.6sec, min. 100~max. 230mA, noise index: 15.86) was used of the pre-contrast and 120kVp, dose modulation(0.6sec, min. 100~max. 275mA, noise index: 15.86) was used of the post-contrast. The glass dosimetry elements were put on left and right phantom thyroid(umbilicus), and the radiation dose without and with the use bismuth(Pb) shield were measured three times.
4. In the abdomen examination, 120kVp and dose modulation(0.6sec, min. 100~max. 300mA, noise index: 11.57) used for examination. The glass dosimetry elements were put on the both nipples of phantom breast(gonad), and the radiation dose without and with bismuth shield were measured three times.
Results
1. In brain CT scanning, shielding with bismuth of lens of eyeballs decreased the radiation dose about 46%(without: 43.98mGy, with: 23.86mGy) and shielding with Pb of thyroid decreased the radiation dose about 24%(without: 1.21mGy, with: 0.92mGy).
2. In neck CT scanning, shielding with bismuth of lens of eyeballs decreased the radiation dose about 42%(without: 66.47mGy, with: 38.58mGy) and shielding with Pb of breast decreased the radiation dose about 65%(without: 2.43mGy, with: 0.86mGy).
3. In chest CT scanning, shielding with bismuth of thyroid decreased the radiation dose about 22%(without: 20.74mGy, with: 16.1mGy) and shielding with Pb of umbilicus decreased the radiation dose about 44%(without: 1.34mGy, with: 0.75mGy).
4. In abdomen CT scanning, shielding with bismuth of breast decreased the radiation dose about 13%(without: 1.80mGy, with: 1.58mGy) and shielding with bismuth of gonad decreased the radiation dose about 33%(without: 23.08mGy, with: 15.46mGy).
Conclusion
According to the study, a percentage of the measured dose reduction is from min. 22% to max. 65%. The results have important meaning that there is much possibility of additional dose reduction through shielding not only in-plane but also out-plane. Consequently, the radiation dose given to patients can be decreased through the CT workers’ effort and concern like shielding out-plane from radiation.
목차
Abstract
Ⅰ. 목적
Ⅱ. 재료 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
- 심부정맥혈전증 검사시 Tracker 기법의 유용성 평가
- CT검사로 인한 방사선 피폭이 혈액에 미치는 생물학적 변화에 관한 연구
- Multi-detector CT장치의 저대조도분해능 평가
- 생체 부분 간이식에서 CT영상을 이용한 간 체적계산법의 Reference Data로서의 유용성
- Small Pulmonary Nodule Localization을 위한 CT Fluoroscopy의 유용성
- 관상동맥 CT혈관조영술에서의 운동 인공물에 대한 심전도 보정에 의한 영상재구성 기법
- CT검사시 조영제의 혈관외유출 발생률 감소를 위한 방안 모색
- 다절편 전산화단층촬영을 이용한 관상동맥촬영의 통계적 고찰
- CT검사시 목적장기 이외 부위의 차폐를 통한 피폭선량감소 효과에 관한 연구
- 경부 CT검사시 선속경화현상 감소를 위한 환자 자세 및 영상 평가
- Dual Energy를 이용한 CT Discography의 평가 방법에 관한 연구
- Dual Source CT를 이용한 폐정맥 검사시 전향적 심전도 동조화 기법의 유용성 평가
- 상지의 Direct Injection CT Venogram의 유용성에 대한 고찰
- 골밀도 측정에 있어 3D-QCT와 DXA의 유용성 비교
- 64 Slice MDCT와 심근관류 SPECT, 심초음파를 이용한 심실 기능 지표의 비교
- Cardiac CTA의 조영제 주입시간에 관한 연구
- 급성 뇌경색 환자의 혈전용해제(tPA) 투여를 위한 BEST Protocol의 유용성
- Dose Modulation 기법에서 Noise Index 변화에 따른 선량 및 영상 Noise의 변화
- 대한전산화단층기술학회지에 게재된 논문의 연구동향
- 관상동맥 CT조영 검사시 선량감소 프로토콜에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!