본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Cardiac CTA의 조영제 주입시간에 관한 연구

이용수 9

영문명
The study About Injection Time of The Contrast Media at Cardiac CT Angigraphy
발행기관
대한CT영상기술학회
저자명
김창곤(Chang Kon Kim) 허재윤(Jae Yun Heo) 고창수(Chang Su Ko) 범희남(Hee Nam Bum) 선종백(Jong Baek Seon)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제11권 제1호, 53~59쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose This study was to survey contrast media washout time in right atrium(RA) using time bolus and saline push method. And, we have compared routine injection with changed injection method in order to obtain the excellent images without streak artifacts at cardiac computed tomographic angiography(CTA). Materials and methods We have inspected 50 people those who had scanned CT during November, 2008. After preparing intravenous route in medial-cubital vein at elbow joint of right side, we had performed the test bolus at the ascending aorta. We attained enhance peak time and injected the combination of contrast media(CM) and saline(CM: 60cc, 4cc/sec ; saline: 50cc, 5cc/sec). Then we acquired contrast media washout time in RA to below 300HU. We have selected 45 people those who had scanned cardiac CTA between October to November 2005. We divided them to 3 groups(group A: CM 70cc, 4.0/sec ; saline 30cc, 4.0/sec, group B: CM 75cc, 4.0/sec ; saline 30cc, 4.0/sec, group C: CM 80cc, 4.0/sec ; saline 30cc, 4.0/sec) and evaluated in the quantitative and qualitative way. We have performed 50 people those who had scanned cardiac CTA using changed volume method(group D) and evaluated in and qualitative way during January, 2009. Results 1. At the time curve coordinates against HU of RA, contrast media washout time takes 23sec in 15 and takes 24sec in 35 people to below 300HU. It means that takes about 9sec after injection contrast media. 2. Group D is superior to other groups(A, B, C) in the quantitative way. 3. Group D is superior to other groups(A, B, C) in the qualitative way. Conclusion According to the results contrast media washout time has regularity and changed volume method helped to obtain excellent image without streak artifacts.

목차

Abstract
Ⅰ. 목적
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김창곤(Chang Kon Kim),허재윤(Jae Yun Heo),고창수(Chang Su Ko),범희남(Hee Nam Bum),선종백(Jong Baek Seon). (2009).Cardiac CTA의 조영제 주입시간에 관한 연구. 대한CT영상기술학회지, 11 (1), 53-59

MLA

김창곤(Chang Kon Kim),허재윤(Jae Yun Heo),고창수(Chang Su Ko),범희남(Hee Nam Bum),선종백(Jong Baek Seon). "Cardiac CTA의 조영제 주입시간에 관한 연구." 대한CT영상기술학회지, 11.1(2009): 53-59

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제