본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

당뇨황반부종에서 시간과 스펙트럼 도메인 빛간섭단층촬영으로 측정한 황반두께의 반복성과 일치도

이용수 37

영문명
Repeatability and Agreement of Macular Thickness Measurement Using Time and Spectral Domain OCT in Diabetic Macular Edema
발행기관
대한안과학회
저자명
오세범 문준웅 김형찬,Se Beum Oh, MD, Jun Woong Moon, MD, Hyung Chan Kim, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume51,number3, 372~378쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2010.03.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the repeatability of macular thickness measurements using time domain (TD) OCT and spectral domain (SD) OCT in diabetic macular edema. Methods: In 42 eyes of 42 patients with diabetic macular edema, three consecutive macular measurements were performed with TD OCT and SD OCT, and measurements for macular thickness and total macular volume obtained by the two OCTs were compared. The within-subject standard deviation (Sw), coefficient of variation (CVw), and intraclass correlation coefficient (ICC) were calculated to assess repeatability, with agreement between measurements assessed with Bland Altman plots. The correlations were also evaluated via the Pearson’s correlation coefficient. Results: The Sw of TD OCT and SD OCT for foveal thickness, total macular volume were 29.67 μm/16.44 μm, 1.26 mm3/0.23 mm3, respectively, and were significantly lower in SD OCT. The ranges of the respective CVw and ICC values were 1.10-2.78%, 0.78~0.96 for TD OCT, and 0.29~0.94%, 0.92~0.99 for SD OCT. The SD OCT showed better repeatability for macular thickness measurements (all p≤0.001). The 95% limits of agreement for foveal and total macular volume were 88.9 μm, 2.4 mm3, respectively. The Pearson’s correlation coefficients of macular thickness and total macular volume between the two OCT methods were statistically significant (p=0.88-0.99). Conclusions: Although both OCTs proved reliable for macular thickness measurements in diabetic macular edema, SD OCT shows better repeatability than TD OCT. Although macular thickness measurements obtained from the two OCTs cannot be used interchangeably, there were statistically significant correlations between measurements obtained using the two OCTs. J Korean Ophthalmol Soc 2010;51(3):372-378

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

오세범,문준웅,김형찬,Se Beum Oh, MD, Jun Woong Moon, MD, Hyung Chan Kim, MD, PhD. (2010).당뇨황반부종에서 시간과 스펙트럼 도메인 빛간섭단층촬영으로 측정한 황반두께의 반복성과 일치도. 대한안과학회지, 51 (3), 372-378

MLA

오세범,문준웅,김형찬,Se Beum Oh, MD, Jun Woong Moon, MD, Hyung Chan Kim, MD, PhD. "당뇨황반부종에서 시간과 스펙트럼 도메인 빛간섭단층촬영으로 측정한 황반두께의 반복성과 일치도." 대한안과학회지, 51.3(2010): 372-378

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제