본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

미세각막절개도를 이용하여 얻은 돼지눈 표층이식편의 두께 및 지름 예측성

이용수 2

영문명
Predictability of Donor Lamellar Graft Thickness and Diameter Using a Microkeratome in Porcine Eyes
발행기관
대한안과학회
저자명
김무상 이승찬 이승준 진경현,Moo Sang Kim, M.D., Seung Chan Lee, M.D., Seung Jun Lee, M.D., Kyung Hyun Jin, M.D.
간행물 정보
『대한안과학회지』Ophthalmological Society,volume48,number4, 473~477쪽, 전체 5쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the thickness and diameter of a lamellar graft with microkeratome and to determine its usefulness as a donor lamellar graft for microkeratome-assisted lamellar keratoplasty. Methods: Thirty-six porcine eyes were randomly assigned to three groups according to the microkeratome (Automated Corneal Shaper?) depth plate : group 1 (#300 ?m plate, 13 eyes), group 2 (#400 ?m plate, 12 eyes), and group 3 (#450 ?m plate, 11 eyes). Free corneal buttons were made with the corneal shaper after a uniform suction duration of 10 seconds. Central corneal thicknesses were measured with an automated ultrasound pachymeter prior to the procedure. After the lamellar graft was made, the remaining corneal thickness was measured with the same method. The difference between the two values was hypothesized to be the lamellar graft thickness. In addition, the diameter of lamellar graft was measured by calipers. Results: The mean lamellar graft thicknesses in groups 1, 2, and 3 were 218.2±26.6 ?m (72.7%), 312.3±26.7 ?m (78.1%) and 345.7±36.7 ?m (76.8%), respectively. There were no significant differences between the three groups according to the results brought by the microkeratome depth plates (p=0.239). The mean lamellar graft diameters in groups 1, 2, and 3 were 8.49±0.28 mm, 8.43±0.26 mm and 8.58±0.28 mm, respectively. There were no significant differences between the three groups (p=0.368). No relationship was found between lamellar graft thickness and diameter (r=-0.009, p=0.480). Conclusions: These results suggest that in forming donor lamellar grafts with microkeratome plates, thicker resection depth is needed because the actual lamellar graft were shown to be thinner than the target values. However, lamellar grafting is thought to be unsuitable for lamellar keratoplasty because it results in considerable thickness variability.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김무상,이승찬,이승준,진경현,Moo Sang Kim, M.D., Seung Chan Lee, M.D., Seung Jun Lee, M.D., Kyung Hyun Jin, M.D.. (2007).미세각막절개도를 이용하여 얻은 돼지눈 표층이식편의 두께 및 지름 예측성. 대한안과학회지, 48 (4), 473-477

MLA

김무상,이승찬,이승준,진경현,Moo Sang Kim, M.D., Seung Chan Lee, M.D., Seung Jun Lee, M.D., Kyung Hyun Jin, M.D.. "미세각막절개도를 이용하여 얻은 돼지눈 표층이식편의 두께 및 지름 예측성." 대한안과학회지, 48.4(2007): 473-477

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제