본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

저강도 초음파치료의 골절치유 효과

이용수 44

영문명
Effect of Low-Intensity Ultrasound on Bone Growth
발행기관
한국전문물리치료학회
저자명
이충휘(Yi Chung-hwi) 김종만(Kim Jong-man) 황태선(Hwang Tae-sun)
간행물 정보
『한국전문물리치료학회지』한국전문물리치료학회지 제5권 제3호, 34~41쪽, 전체 8쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
1998.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Noninvasive low intensity ultrasound has been shown to be an effective means of accelerating bone fracture repair in both animal and clinical studies. The effects of ultrasound stimulation on bone repair after fibular osteotomy were assessed in a rabbit fibular fracture model. Bilateral closed fibular fractures were made in skeletally mature male White Japanese rabbits. In this study, 24 subjects were randomly divided into 2 groups: experimental group 1 (n=12), and experimental group 2 (n=12). Experimental group 1 received 0.875㎒ continuous ultrasound and Experimental group 2 was treated with 3㎒ continuous ultrasound. The ultrasound intensity was 50 ㎽/㎠ and treatment time was 10 minutes for every session in both groups. In each rabbit, one fibula served as a control and the other was subjected to ultrasound treatment 5 times per week for 3 weeks. After 3 weeks, rabbits were sacrificed and the ratios of the area between the trabeculae and bone marrow of the fibulae were calculated. At the end of the experimental period, 14 of the 24 rabbits were excluded due to complications from surgery or inadequate fracture status for this study. There was no statistically significant difference in the trabeculae area between experimental leg and control leg in experimental group 1 and experimental group 2 (p>0.05). And there was also no statistic statistically significant difference between experimental group 1 and experimental group 2 according to ultrasound treatment frequencies, 0.875㎒ and 3㎒ (p>0.05). These data suggest that in Japanese white rabbits, low intensity ultrasound stimulation does not facilitate fracture repair nor is there any difference in fracture repair results between ultrasound frequencies, 0.875㎒ and 3㎒.

목차

Abstract
Ⅰ. 서론
Ⅱ. 연구방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
인용문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이충휘(Yi Chung-hwi),김종만(Kim Jong-man),황태선(Hwang Tae-sun). (1998).저강도 초음파치료의 골절치유 효과. 한국전문물리치료학회지, 5 (3), 34-41

MLA

이충휘(Yi Chung-hwi),김종만(Kim Jong-man),황태선(Hwang Tae-sun). "저강도 초음파치료의 골절치유 효과." 한국전문물리치료학회지, 5.3(1998): 34-41

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제