본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Passive Sampler를 활용한 공단지역의 대기질 평가

이용수 32

영문명
Air Quality Assessment of Industrial Complex Using Passive Sampler
발행기관
대전대학교 환경문제연구소
저자명
김선태(Sun- Tae Kim) 김성근(Sung-Kun Kim) 김학민(Hak-Min Kim) 정의석(Eui-Suk Jung)
간행물 정보
『環境問題硏究所 論文集』第5號, 67~81쪽, 전체 15쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2001.02.28
4,600

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

We used the passive diffusion samplers that are known to be very useful to measure the concentration of air pollutants with respect to the spatial distributions. In this study, we estimated the badge type passive sampler which is evaluation of accuracy and precision and badge type passive sampler is used for the measurement of S0₂ and N0₂ in Pohang, Kunsan, Daejeon industrial complex monthly. Concentration and spatial distribution survey are presented during I years. For SO₂ and NO₂ passive sampler, we made additional two blank samplers for each compound with the passive samplers for the actual measurement. The results of blank test shows that NO₂ is O.29ppb, SO₂ is O.55ppb on basis of the month. Using the results measured at the same places as TMS (telemetering system) sites, the accuracy of the passive sampler could be checked. The measurement data with passive sampler was time weighted average concentration for a month. So, it might be difficult to compare two data directly. Although the correlation between the results of passive sampler and TMS data were not appeared so high, the applicability of passive sampler would be acceptable considering that these data were produced in uncontrolled experiment environment. Monthly variations of average SO₂ concentration in three industrial complex areas was compared. The average SO₂ concentration in Pohang and Kunsan area was appeared to be higher than Daejeon area because Pohang and Kunsan area is much bigger than Daeieon area in the magnitude of industrial complex. Also Pohang area was appeared to be higer than Kunsan area because the measurement data in Pohang area included the data inside the factory's lot. Also, the comparison of NO₂ concentration in each site shows that NO₂ near busy road is higher than residential area and industrial area. It is considered that the measurement of air pollutant using passive sampler is suitable for the areas such as industrial complex widely.

목차

ABSTRACT
1. 서론
2. 실험 재료 및 방법
3. 결과 및 고찰
4. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김선태(Sun- Tae Kim),김성근(Sung-Kun Kim),김학민(Hak-Min Kim),정의석(Eui-Suk Jung). (2001).Passive Sampler를 활용한 공단지역의 대기질 평가. 環境問題硏究所 論文集, (5), 67-81

MLA

김선태(Sun- Tae Kim),김성근(Sung-Kun Kim),김학민(Hak-Min Kim),정의석(Eui-Suk Jung). "Passive Sampler를 활용한 공단지역의 대기질 평가." 環境問題硏究所 論文集, .5(2001): 67-81

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제