The active-knee-extension (AKE) test has been used to measure hamstring muscle length. The traditional AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip fixed by straps, while the stabilized AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip stabilized using a pressure biofeedback unit providing lumbopelvic stabilization. The purpose of this study was to determine test-retest reliability of the traditional AKE test and stabilized AKE test. Twenty healthy adults participated in the study. The popliteal angles were measured with a digital inclinometer during each test. To assess the test-retest reliability between the 2 test sessions, intraclass correlation coefficients (ICCs) were calculated. The intrasubject coefficient of variation (CVintra) was also calculated. To compare the traditional and stabilized AKE tests for changes in pressure, paired t-tests were applied. The results of this study were as follows: 1) ICCs(3,1) value for test-retest reliability was .96 in the traditional AKE test, and was .98 in the stabilized AKE test. 2) The maximal CVintra was 33.7% in the traditional AKE test and 15.7% in the stabilized AKE test. 3) Differences of 6.1±2.1 ㎜Hg in pressure were measured in the traditional AKE test, and differences of 1.2±1.0 ㎜Hg in pressure were measured in the stabilized AKE test. The results show the traditional and stabilized AKE test to be highly reliable, with test-retest reliability. However, the stabilized AKE test represented less variation and more stabilization than the traditional AKE test. Further study is needed to measure the inter-rater reliability of the stabilized AKE test for generalization and clinical application.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Min-hee Kim,Yong-wook Kim,Doh-heon Jung,Chung-hwi Yi. (2009).Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test. 한국전문물리치료학회지, 16 (4), 1-7

MLA

Min-hee Kim,Yong-wook Kim,Doh-heon Jung,Chung-hwi Yi. "Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test." 한국전문물리치료학회지, 16.4(2009): 1-7

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제