본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

WOMAC-VA3.0의 타당도 및 신뢰도 - 일부 슬관절 및 고관절 골관절염환자를 대상으로

이용수 98

영문명
Validity and Reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-VA3.0 in Hip and Knee Osteoarthritis Patients
발행기관
한국전문물리치료학회
저자명
이승주(Seung-ju Yi) 이현주(Hyun-ju Lee) 우영근(Young-keun Woo)
간행물 정보
『한국전문물리치료학회지』한국전문물리치료학회지 제15권 제2호, 20~29쪽, 전체 10쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2008.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

  The purpose of this study was to examine the validity and reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-V A3.0 in patients with hip and knee osteoarthritis(OA). The sample consisted of 301 patients who had received treatments at the physical therapy units of 5 medical institutions in Andong City in june 2006. Questionnaires on the WOMAC were recruited by 12 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency (Cronbach"s alpha coefficient: α), item-discriminant validity, and Pearson"s relation coefficient. To explore construct validity, we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. The average age of the patients was 62.1 years. All WOMAC subscales (pain, stiffness, and physical function) were internally consistent with Cronbach"s coefficients of .81, .91, and .80, respectively. The internal consistency reliability of item-each scale were also internally consistent with Cronbach"s coefficient of .89 (Pearson"s correlation coefficient:   .71~.84), .93 (.89~.91), and .96 (.67~.91), respectively. However, high correlation was found among 3 items (.66~.83,  .66~.67, and .67~.83), so the item-discriminant validity was low ( α coefficient: .81, .91, .80, respectively). The construct validity by factor analysis was low because it was not consistent With WOMAC-VA3.0. In conclusion, the results reported here confirm the reliability of the WOMAC in patients with OA of the hip and knee. The collection of information on the hip and knee osteoarthritis using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.

목차

Abstract
Ⅰ. 서론
Ⅱ. 연구방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
인용문헌
부록1. WOMAC-VA3.0 측정도구의 구성내용

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이승주(Seung-ju Yi),이현주(Hyun-ju Lee),우영근(Young-keun Woo). (2008).WOMAC-VA3.0의 타당도 및 신뢰도 - 일부 슬관절 및 고관절 골관절염환자를 대상으로. 한국전문물리치료학회지, 15 (2), 20-29

MLA

이승주(Seung-ju Yi),이현주(Hyun-ju Lee),우영근(Young-keun Woo). "WOMAC-VA3.0의 타당도 및 신뢰도 - 일부 슬관절 및 고관절 골관절염환자를 대상으로." 한국전문물리치료학회지, 15.2(2008): 20-29

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제