본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Prognosis of 3 mm diameter two-piece implants immediately placed after anterior teeth extraction

이용수 0

영문명
발행기관
대한치과이식임플란트학회
저자명
Jihwan Yoon Kwan-Soo Park
간행물 정보
『Journal of Dental Implant Research』제43권 제4호, 77~82쪽, 전체 6쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2024.12.01
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Implant placement immediately after tooth extraction has many advantages, including fewer surgeries and a shorter treatment period. The procedure is often performed in the anterior teeth that require rapid aesthetic restoration. This study examined the prognosis of two-piece narrow-diameter implants (NDIs) in the implant placement immediately after extracting the mandibular incisors and maxillary lateral incisors that require high strength in narrow locations. This study was conducted using 3.0 mm two-piece NDIs (TS III SA, Osstem Implant Co., Seoul, Korea) placed immediately after anterior tooth extraction at the Inje University Sanggye Paik Hospital Department of Oral and Maxillofacial Surgery from 2017 to 2023. Sixteen implants (three in the maxilla and 13 in the mandible) were placed in 13 patients (four males and nine females). The primary reasons for tooth extraction included periodontal disease, dental caries, and dental trauma. The implant stability quotient (ISQ) values measured by Osstell ISQ were recorded immediately after implant placement and before impression taking. The 3.0 mm two-piece NDIs placed immediately after anterior tooth extraction varied in length: 10.0 mm in six cases, 11.5 mm in seven cases, and 13.0 mm in three cases. Bone grafting was performed in six cases; three implants used both bone grafting and a membrane, and seven implants were placed without bone grafting. Over an average post-prosthetic follow-up of 9.9 months, two 10.0 mm implants placed in the mandibular anterior region failed to osseointegrate. They were re-implanted with a 3.0 mm diameter and 13.0 mm long implant and a 3.5 mm diameter and 13.0 mm long implant, respectively, which were well retained. Two cases of failed osseointegration were encountered in 3.0 mm two-piece NDIs. The remaining implants had stable prognoses. In the mandibular anterior region, the placement of a two-piece NDI immediately after tooth extraction appears to require great care. (JOURNAL OF DENTAL IMPLANT RESEARCH 2024;43(4):77-82)

영문 초록

목차

INTRODUCTION
MATERIALS AND METHODS
RESULT
DISCUSSION
CONCLUSION
ORCID
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Jihwan Yoon,Kwan-Soo Park. (2024).Prognosis of 3 mm diameter two-piece implants immediately placed after anterior teeth extraction. Journal of Dental Implant Research, 43 (4), 77-82

MLA

Jihwan Yoon,Kwan-Soo Park. "Prognosis of 3 mm diameter two-piece implants immediately placed after anterior teeth extraction." Journal of Dental Implant Research, 43.4(2024): 77-82

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제