본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

成犬下顆骨에서 TITANIUM 및 CARBON-COAT ED BLADE-VENT人工齒牙의 周圍組織反應

이용수 2

영문명
THE TISSUE RESPONSE TO TITANIUM AND CARBON-COATED BLADE-VENT IMPLANTS IN THE MANDIBLES OF DOGS
발행기관
대한치과이식임플란트학회
저자명
朴金诛 (Keum-Soo Park) 崔牧均(Mok-Kyun Choie) 金鴻基(Hong-Ki Kim) 金光兹 (Kwang-Hyun Kim) Chang Bae
간행물 정보
『Journal of Dental Implant Research』제7권 제1호, 10~20쪽, 전체 11쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
1986.12.31
4,120

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

In order to investigate the influence o f implant materials, functional stress and width of channel on the tissue reaction around implants, the tissues around the endosseous implants were observed histopathologically. The manflibular left 2nd,3rd and 4th premolars o f 12 healthy dogs (25-40 kg body weight) were extracted. Three months after extraction, pure titanium blade-vent implants (K.L. Blade Implant, DAE WON KANG UP Co., Ltd., KOREA Design by Dr. H.K. KIM) and carbon-coated titanium implants (K.L. Blade Implant, DAE WON KANG UP Co., Ltd., KOREA Design by Dr. H.K. KIM) were implanted into the 3rd premolar regions seperately. For implantation, 12 dogs were divided into 6 groups as follows; GroupⅠ(functional implant); Implantation o f titanium blade-vent implant with cone-shaped chrome-cobalt crown into the narrow channel (width approximately 1 mm, which was almost equal to that o f implant). GroupⅡ(non-functional implant); Implantation of titanium balde-vent implant without head into the narrow channel (width approximately 1 mm). A GroupⅢ(non-functional implant); Implantation of titanium blade-vent implant without head into the wide channel (width approximately 2.5 mm, which was 1.5 mm wider than that of implant). GroupⅣ(functional implant); Implantation of carbon-coated blade-vent implant by the same method as group I. GroupⅤ(non-functional implant); Implantation of carbon-coated implant by the same method as groupⅡ. GroupⅥ(non-functional implan狀 Implantation o f carbon-coated implant by the same method as groupⅢ. Six months after implantation, the tissue blocks containing the implants were removed. These block sections were fixed in 10% neutral buffered formalin for 2 days and decalcified in 15% formic acid. The buccal side of the blocks were removed with a knife and the implants were detached from the blocks. The tissue blocks were embedded by paraffin embedding method and then sectioned by 5-7 jum thickness. Those specimens were stained with hematoxylin and eosin. The results obtained were as follows. 1. Fibrous capsules existed around the functional implants, but were not observed around the non-functional implants embedded into the narrow channels. 2. Fibrous capsules were observed around the implants inserted into the wide channel even though they were embedded into the bone. 3. There was little difference between the tissue reaction to the pure titanium implants and that to the carbon-coated implants. 4. No abnomal changes were found in the fibrous connective tissue and the osseous tissue around the titanium and carbon-coated implants.

목차

Ⅰ. 서 론
Ⅱ. 실험재료 및 방법
Ⅲ. 실험결과
Ⅳ. 고 찰
Ⅴ. 결 론
REFERENCE

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

朴金诛,(Keum-Soo Park),崔牧均(Mok-Kyun Choie),金鴻基(Hong-Ki Kim),金光兹,(Kwang-Hyun Kim),Chang Bae. (1986).成犬下顆骨에서 TITANIUM 및 CARBON-COAT ED BLADE-VENT人工齒牙의 周圍組織反應. Journal of Dental Implant Research, 7 (1), 10-20

MLA

朴金诛,(Keum-Soo Park),崔牧均(Mok-Kyun Choie),金鴻基(Hong-Ki Kim),金光兹,(Kwang-Hyun Kim),Chang Bae. "成犬下顆骨에서 TITANIUM 및 CARBON-COAT ED BLADE-VENT人工齒牙의 周圍組織反應." Journal of Dental Implant Research, 7.1(1986): 10-20

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제