본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Clinical Performance Comparison of Ultrahigh-speed Dual Pneumatic Vitrectomy Probes: Is Faster and Smaller Better?

이용수 0

영문명
Clinical Performance Comparison of Ultrahigh-speed Dual Pneumatic Vitrectomy Probes: Is Faster and Smaller Better?
발행기관
대한안과학회
저자명
Donghyeon Lee Sooyeon Lee Kyung Seek Choi
간행물 정보
『The Korean Journal of Ophthalmology』Vol.38 No.2, 122~128쪽, 전체 7쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2024.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Various vitrectomy probes are currently being used commercially, and there are ongoing efforts toward developing probes with higher cutting rates and smaller gauges. This study aimed to compare the efficiency and safety of various commercially available small gauge ultrahigh-speed dual pneumatic vitrectomy probes. Methods: We retrospectively analyzed the medical records of patients and recorded intraoperative videos while they underwent microincision three-port vitrectomy surgery for idiopathic epiretinal membrane at Soonchunhyang University Seoul Hospital. The patients were categorized into four groups based on the vitrectomy probe used during surgery: 23-7500 (UltraVit 23-gauge 7,500 cuts per minute [CPM]), 23-7500 (UltraVit 25-gauge 7,500 CPM), 25-10K (Advanced UltraVit 25-gauge 10,000 CPM), and 27-10K (Advanced UltraVit 27-gauge 10,000 CPM). Results: In total, 82 eyes from 82 patients were included in this work, with 16, 11, 26, and 29 eyes in groups 23-7500, 25- 7500, 25-10K, and 27-10K, respectively. The corresponding vitrectomy times were 295.56 ± 53.55, 293.09 ± 50.28, 299.92 ± 59.42, and 349.38 ± 67.23 seconds, respectively. There was a significant difference in the vitrectomy time between the groups (p = 0.004). The mean number of sutures was 3, 3, 2.96, and 0.83, respectively. In the 23-7500 group, there was one case of iatrogenic retinal break, while in the 27-10K group, there was one case of postoperative hypotony. Conclusions: Although advancements have been made in the 27-gauge vitrectomy probe, it still takes more vitrectomy time than it does when using the 23- and 25-gauge probes. However, the delay was within an average of 1 minute, and considering the significantly reduced need for sutures, there is a substantial benefit in terms of postoperative discomfort. Therefore, when choosing a probe for epiretinal membrane surgery among the four options, it is reasonable to select the 27-gauge probe according to the surgeon’s preference.

목차

Materials and Methods
Results
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Donghyeon Lee,Sooyeon Lee,Kyung Seek Choi. (2024).Clinical Performance Comparison of Ultrahigh-speed Dual Pneumatic Vitrectomy Probes: Is Faster and Smaller Better?. The Korean Journal of Ophthalmology, 38 (2), 122-128

MLA

Donghyeon Lee,Sooyeon Lee,Kyung Seek Choi. "Clinical Performance Comparison of Ultrahigh-speed Dual Pneumatic Vitrectomy Probes: Is Faster and Smaller Better?." The Korean Journal of Ophthalmology, 38.2(2024): 122-128

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제