본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Study on the Smoke and CO Alarm Concentrations to Develop a Smoke & CO Combination Detector

이용수 0

영문명
Study on the Smoke and CO Alarm Concentrations to Develop a Smoke & CO Combination Detector
발행기관
한국화재소방학회
저자명
Sikuk Kim
간행물 정보
『International Journal of Fire Science and Engineering』Vol. 37, No. 4, 43~52쪽, 전체 10쪽
주제분류
공학 > 공학일반
파일형태
PDF
발행일자
2023.12.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

In this study, we studied smoke and CO alarm concentrations to develop a combination detector for both smoke and CO. The derivation of smoke and CO alarm concentrations involved examining CO concentrations by smoke concentration using a sensitivity tester, typically employed for the type approval of photoelectric smoke detectors. Fire alarm and false alarm tests were performed to analyze smoke and CO concentrations further. In the fire alarm test conducted with polyurethane foam, generating black smoke with a reduced light scattering effect in the smoke chamber, no fire alarm was triggered, although the fire alarm concentration of the existing photoelectric smoke detector of sensitivity type 2 was set at 15 %/m. The measured smoke concentration reached only up to 10.2 %/m. Conversely, in the false alarm test with sliced pork belly and mackerel, false alarms occurred as the smoke concentration exceeded 15 %/m. The determined smoke and CO alarm concentrations for the combination detectors were established at 7.5 %/m for smoke (continuously for 10 s) and 15 ppm for CO (continuously for 10 s). Applying these concentrations in subsequent tests revealed an improved performance. In the polyurethane foam fire, where the existing smoke detector failed to operate, a fire alarm was issued at 328 s with the newly derived concentrations. For smoldering wood, the combination detector issued a fire alarm 305 s faster than the existing smoke detector. Furthermore, in the false alarm test with hamburger patty, sliced pork belly, and mackerel, the adaptability of false alarms was enhanced.

목차

1. Introduction
2. Experiment
3. Experiment Results
4. Conclusions
Conflicts of Interest
Acknowledgment
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Sikuk Kim. (2023).Study on the Smoke and CO Alarm Concentrations to Develop a Smoke & CO Combination Detector. International Journal of Fire Science and Engineering, 37 (4), 43-52

MLA

Sikuk Kim. "Study on the Smoke and CO Alarm Concentrations to Develop a Smoke & CO Combination Detector." International Journal of Fire Science and Engineering, 37.4(2023): 43-52

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제