본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구

이용수 0

영문명
Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
김정수 김근우
간행물 정보
『방사선기술과학』제46권 제5호, 401~408쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2023.10.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of im-ages acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid up-take system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the proto-col of thyroid scan test (99mTcO4-, 370 MBq) in normal results, 99mTcO4- was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 ㎝). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when us-ing the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was stat-istically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thy-roid disease.

목차

Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김정수,김근우. (2023).갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구. 방사선기술과학, 46 (5), 401-408

MLA

김정수,김근우. "갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구." 방사선기술과학, 46.5(2023): 401-408

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제