Baseline Correction in Computed Radiography Images with 1D Morphological Filter

이용수 18

영문명
Baseline Correction in Computed Radiography Images with 1D Morphological Filter
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
김용권(Yong-Gwon Kim) 류연철(Yeunchul Ryu)
간행물 정보
『방사선기술과학』제45권 제5호, 397~405쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2022.10.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

목차

Ⅰ. Introduction
Ⅱ. Materials and Methods
Ⅲ. Results
Ⅳ. Discussion
Ⅴ. Conclusions
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김용권(Yong-Gwon Kim),류연철(Yeunchul Ryu). (2022).Baseline Correction in Computed Radiography Images with 1D Morphological Filter. 방사선기술과학, 45 (5), 397-405

MLA

김용권(Yong-Gwon Kim),류연철(Yeunchul Ryu). "Baseline Correction in Computed Radiography Images with 1D Morphological Filter." 방사선기술과학, 45.5(2022): 397-405

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제