본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석

이용수 34

영문명
Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel
발행기관
한국환경보건학회
저자명
유한조(Han-Jo You) 정연훈(Yeon-Hoon Jung) 김진길(Jin-guil Kim) 신형순(Hyung-Soon Shin) 임윤정(Yoon-Jung Lim) 이상수(Sang-Soo Lee) 손해준(Hae-Jun Son) 임삼화(Sam-Hwa Lim) 김종수(Jong-Su Kim)
간행물 정보
『1. 한국환경보건학회지』제46권 제6호, 719~725쪽, 전체 7쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2020.12.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 µm diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 µm and larger than 2.5 µm, and particulate matter of 2.5 µm or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 µm. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during mergency reduction measures.

목차

I. 서 론
II. 연구대상 및 방법
III. 결 과
IV. 고 찰
V. 결 론
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

유한조(Han-Jo You), 정연훈(Yeon-Hoon Jung), 김진길(Jin-guil Kim), 신형순(Hyung-Soon Shin), 임윤정(Yoon-Jung Lim), 이상수(Sang-Soo Lee), 손해준(Hae-Jun Son), 임삼화(Sam-Hwa Lim), 김종수(Jong-Su Kim). (2020).고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석. 1. 한국환경보건학회지, 46 (6), 719-725

MLA

유한조(Han-Jo You), 정연훈(Yeon-Hoon Jung), 김진길(Jin-guil Kim), 신형순(Hyung-Soon Shin), 임윤정(Yoon-Jung Lim), 이상수(Sang-Soo Lee), 손해준(Hae-Jun Son), 임삼화(Sam-Hwa Lim), 김종수(Jong-Su Kim). "고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석." 1. 한국환경보건학회지, 46.6(2020): 719-725

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제