국문 초록
영문 초록
Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes.
Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas.
Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 µm diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 µm and larger than 2.5 µm, and particulate matter of 2.5 µm or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 µm. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor.
Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during mergency reduction measures.
목차
I. 서 론
II. 연구대상 및 방법
III. 결 과
IV. 고 찰
V. 결 론
References
키워드
해당간행물 수록 논문
- 고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석
- 실험동물 랫드를 이용한 미세먼지 기도노출에 따른 호흡기계 독성에 대한 마늘의 예방효과 탐색
- 운행 중 대중교통차량 내 부유진균 농도 분석
- 울산지역 초등학교 학생에서 대기중 꽃가루 비산 수준과 흡입 알레르겐 감작률과의 관련성
- 공주시 노인의 주관적 건강 지식과 환경 노출 저감 행동의 관련성
- 2020년 코로나바이러스감염증-19 유행 상황에서 서울시 다중이용 시설 및 실외에서의 마스크 착용 행태
- 곰팡이에 감작된 소아 천식 환자 가정내 환경유해물질 농도와 폐기능의 상관관계
- 요인 및 군집분석을 이용한 유해화학물질 사고 잠재적 피해에 대한 도시 유형 분류 및 특성 분석
- 경기도 해수욕장 모래의 안전성 확보를 위한 선행연구
- 경기도내 물놀이형 수경시설 중 미생물 분포 조사 연구
- 폐금속광산 지역 주민들의 요 중 비소종별 농도와 관련요인 평가
- 동물 분변으로 인한 모래 바닥재의 오염실태 및 관리 방안에 관한 연구 -질소분석방법개발-
- 손소독제 사용 실태 조사 및 성분 분석
- 피톤치드 기상서비스 예측 모델링 적용을 위한 발생특성 및 기상인자 조사
- Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가
- [편집인 글] 한국환경보건학회지의 현황 고찰
- 정오 “가습기 살균제 제품의 건강위험 고찰 - 제품 수와 살균제 성분을 중심으로 -”
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!