PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정

이용수 8

영문명
Scattering Measurement of Syringe Shield Used in PET/CT
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
장동근(Dong-Gun Jang) 박철우(Cheol-Woo Park) 박은태(Eun-Tae Park)
간행물 정보
『방사선기술과학』방사선기술과학 제43권 제5호, 375~382쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2020.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

목차

Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

장동근(Dong-Gun Jang),박철우(Cheol-Woo Park),박은태(Eun-Tae Park). (2020).PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정. 방사선기술과학, 43 (5), 375-382

MLA

장동근(Dong-Gun Jang),박철우(Cheol-Woo Park),박은태(Eun-Tae Park). "PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정." 방사선기술과학, 43.5(2020): 375-382

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제