원전 비상디젤발전기실에의 미분무수 소화설비 적용 연구

이용수 138

영문명
An Application Study of Water Mist Fire Extinguishing System in Emergency Diesel Generator Room of Nuclear Power Plant
발행기관
한국화재소방학회
저자명
하각현 이재호 신원규
간행물 정보
『한국화재소방학회 학술대회논문집』2019년도 추계학술대회 논문집, 77~77쪽, 전체 1쪽
주제분류
공학 > 공학일반
파일형태
PDF
발행일자
2019.11.30
무료

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Because carbon dioxide is heavier than air, it is easy to penetrate deep into the fire, and the latent heat of vaporization is large, so it has excellent fire extinguishing ability in a confined space. For this reason, fire extinguishing systems using carbon dioxide are installed in emergency diesel generator (EDG) rooms of most domestic nuclear power plants. However, flooding type carbon dioxide fire extinguishing systems applied to the EDG rooms are difficult to meet the fire extinguishing performance test standards and may negatively affect human safety. Since the water mist fire extinguishing system uses water as the fire extinguishing agent, it is environmentally friendly and does not adversely affect the human body. Thus, it has been replacing gas-based fire extinguishing systems such as carbon dioxide and Halon. In addition, since it has effective fire extinguishing performance even with a small amount, its application is being expanded to industrial facilities where it is difficult to supply a large amount of water. For example, the use of water mist fire extinguishing systems has been increasing in aircraft, naval warships, submarines, subways, machine rooms of ground industrial facilities, and substations. The field in which the water mist fire extinguishing system is most actively applied is in the ship field. International Maritime Organization (IMO) has developed IMO MSC/circ 1165 as a standard to approve the performance of the water mist fire extinguishing system in engine rooms of ships. Therefore, in order to apply a water mist fire extinguishing system to a ship, this standard must be satisfied. The U.S. Nuclear Regulatory Commission Regulatory Guide (USNRC RG 1.189) permit the use of the water mist fire extinguishing systems in accordance with NFPA 750. However, there are no technical standards and approval procedures for the performance test of water mist fire extinguishing systems specialized in nuclear power plant design. Therefore, in this study, the performance of the water mist nozzle applicable to the nuclear power plant was numerically evaluated using the IMO 1165 standard for the purpose of applying the water mist fire extinguishing system to a nuclear power plant. The performance evaluation of the water mist nozzle was performed using FDS (Fire Dynamics Simulator) 6.5.2 developed by NIST. As a result of the simulation, the water mist fire extinguishing system satisfies both the fire extinguishing time of 15 minutes (900 seconds), which is the performance standard of IMO 1165, and the room temperature within 100℃.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

하각현,이재호,신원규. (2019).원전 비상디젤발전기실에의 미분무수 소화설비 적용 연구. 한국화재소방학회 학술대회논문집, 2019 (3), 77-77

MLA

하각현,이재호,신원규. "원전 비상디젤발전기실에의 미분무수 소화설비 적용 연구." 한국화재소방학회 학술대회논문집, 2019.3(2019): 77-77

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제