학술논문
Optical spectroscopy of Tb³+ ions doped NaCa(PO₃)₃ phosphors
이용수 46
- 영문명
- Tb³+ 이온이 첨가된 NaCa(PO₃)₃ 형광체의 형광특성
- 발행기관
- 한국방사선학회
- 저자명
- Changyong Yoon()
- 간행물 정보
- 『한국방사선학회 논문지』 제12권 제4호, 451~457쪽, 전체 7쪽
- 주제분류
- 공학 > 기타공학
- 파일형태
- 발행일자
- 2018.08.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
Luminescence properties of NaCa(PO₃)₃ doped with Tb³+ ions are investigated by optical and laser excitation spectroscopy. The phosphors were prepared by solidstate reaction method The X-ray diffraction(XRD) was used to analyze the crystal structure and the crystallinity of the samples. The excitation and emission spectra and decay curve of NaCa(PO₃)₃ : Tb³+ (0.01~30mol%) were measured at room temperature. The f-d band of Tb³+ is observed in the excitation spectra of NaCa(PO₃)₃:Tb³ in the wave length region 205~245nm. Strong emission lines due to the 5 D₄→ 7 F J transition and weak emission lines due to the 5 D₄→ 7 F J transition are observed in the emission spectra of NaCa(PO₃)₃: Tb³+. The energy transfer and cross relaxation between Tb³+ ions are discussed in NaCa(PO₃)₃: Tb³+ in the emission spectra and life time.
영문 초록
Tb 3+ 이온이 첨가된 NaCa(PO₃)₃ 형광체의 여기 및 방출 스펙트럼 및 레이저 분광 측정을 통하여 형광특성을 조사 하였다. 고상법으로 NaCa(PO₃)₃:Tb³+ 형광체를 합성하였다. X선 회절측정(XRD)을 사용하여 형광체의 결정 구조 및 결정성을 분석하여 Tb³+ 이온이 30 mol%까지 첨가되어도 형광체의 결정구조가 NaCa(PO₃)₃의 결정상을 유지하였다.
NaCa(PO₃)₃: Tb³+ (0.01-30mol %)형광체의 여기 및 방출 스펙트럼과 형광의 감쇠곡선을 상온에서 측정 하였다.
NaCa(PO₃)₃ :Tb³+ 의 여기 스펙트럼에서 205~245 nm 영역에서 넓은 Tb³+ 의 4f-5d 전이에 의한 f-d 밴드가 나타났다. NaCa(PO₃)₃ :Tb³+ 의 방출 스펙트럼에서 5D₄→ 7 F J 전이에 의한 강한 피크와 5 D₃→ 7 F J 전이에 약한 피크가 관찰 되었다. 방출 스펙트럼의 형광 강도와 형광의 수명시간 분석을 통하여 Tb³+ 이온 사이의 에너지 전이 및 교차 이완이 확인되었다.
목차
Ⅰ. INTRODUCTION
Ⅱ. MATERIAL AND METHODS
Ⅲ. RESULTS
Ⅳ. DISCUSSION
Ⅴ. CONCLUSION
해당간행물 수록 논문
- The Study of Effectiveness in a Modified Rib Oblique Projection View Using a Chest Phantom
- Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence
- Journal of the Korean Society of Radiology Vol. 12, No. 4 목차
- Application of Wiener filter to Chest CR images
- A Study on the Selection of the Main Factors of Radiation Risk Index Model for assessing risk in Nondestructive Test workplace
- Improvement of Image Compression Using Quantization Technique in Computed Tomography Images
- Reduced Effect of kV-CBCT Dose by Use of Shielding Materials in Radiation Therapy
- Effects of Magnetic Resonance Imaging on the Human Body
- A Study on Non-Subtraction and Subtraction Technique in 3-Dimensional Angiography of the Cerebral Aneurysm
- Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation
- Assessment of Pass Prediction of Radiologist s license on Academic Achievement through Health law Courses of 3rd Year Students in Radiology Department of College(Focus on D Health College)
- Optical spectroscopy of Tb³+ ions doped NaCa(PO₃)₃ phosphors
- Feasibility Study of Applying the Acrylic Assistant Equipment (ACR) to Reduce Patient s Discomfort in Lower Abdomen MRI Scan
- A Study on Improvement of Image Quality Decrease due to Tooth Restoration in Facial CT
- Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!