IV Catheter Gauge에 따른 PSI 유용성 평가

이용수 20

영문명
Evaluation of PSI Effectiveness by IV Catheter Gauge : According to Viscosity of Contrast Media, Temperature, and Connection Tools
발행기관
대한CT영상기술학회
저자명
서윤희(Yun Hee Seo) 김경숙(Kyoung Sook Kim) 김정훈(Jeong Hoon Kim) 김선기(Seon Ki Kim) 김영미(Young Mi Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제2호, 71~80쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose It aims to confirm the pressure difference between the cases of normal saline injection and contrast media injection using power injector, and to prevent the adverse events such as extravasation and so on, comparing PSI according to each condition like securing the vessel of gauge to meet the exam flow rate, maintenance of temperature, selection of connection tool, etc, and injecting the contrast media with the optimum conditions. Materials and methods 18G, 20G, 22G, and 24G catheter were inserted into 50 cm rubber, and connected with 3-way, MRVLS, 18G needle+ injection cap, directly, and with the coil of injector syringe. Injected the normal saline using power injector with the flow rates of 2.0, 2.5, 3.0, 4.0, and 5.0cc/sec, and inject contrast media, Ultravist 300, Ultravist 370, Iopamiro 300, Optiray320, and Visipaque 320, under the same conditions. And injected the contrast media with the temperature change 25℃ and 37℃. Results PSI during the contrast media injection with power injector was measrned twice to 5 times as high as the one during the normal saline injection. The lower the viscosity of contrast media, the higher the temperature, the thicker the catheter gauge, the lower the flow rate was, the lower PSI was measured. Conclusion 3-way, MRVLS, direct connection in the high flow exam is useful, while 3-way, direct connection is useful in the low flow exam and the cases that the vessel is weak. The vessel stability test for the injection solution should be performed accurately considering the difference of contrast media viscosity and standardized to use the contrast media in the heating cabinet since the viscosity may be varied approximately one-and-a half times according to the temperature of contrast media. Further objective experimental studies are required to anticipating the resistance of blood vessel by the patients’ diseases and IV site based on this study.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

서윤희(Yun Hee Seo),김경숙(Kyoung Sook Kim),김정훈(Jeong Hoon Kim),김선기(Seon Ki Kim),김영미(Young Mi Kim). (2010).IV Catheter Gauge에 따른 PSI 유용성 평가. 대한CT영상기술학회지, 12 (2), 71-80

MLA

서윤희(Yun Hee Seo),김경숙(Kyoung Sook Kim),김정훈(Jeong Hoon Kim),김선기(Seon Ki Kim),김영미(Young Mi Kim). "IV Catheter Gauge에 따른 PSI 유용성 평가." 대한CT영상기술학회지, 12.2(2010): 71-80

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제