학술논문
초음파검사에 의한 간 크기 측정방법 및정상 성인의 체격지수별 참조범위
이용수 22
- 영문명
- Liver Size Measurement Method by Ultrasonography and Reference Range based on Normal Adult Physique Index
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 김용균(Yong-Kyun Kim) 한동균(Dong-Kyoon Han)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제41권 제1호, 1~12쪽, 전체 12쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2018.02.28
4,240원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Liver size is an important component in the diagnosis and follow-up of diffuse liver disease when testing for liver disease using ultrasonography. However, difficulties lies in determining the presence of hepatomegaly and liver atrophy because the method used for measuring liver size differs from one examiner to another and there is no relevant standard based on body build. The present study aims to propose a more objective method for liver size measurement and a reference range based on body build.
A total of 260 normal adults (130 males, 130 females) participated in the study. Ultrasonography was performed in all participants to measure the size of the right lobe, left lobe, quadrate lobe, and caudate lobe of liver. Based on Physique Index(PI), a value derived from multiplying weight(kg) by height(m 2 ), size of physique was divided into three groups including Group I with PI<150, Group II with 150≤PI≤250, and Group III with PI>250. Thus, mean liver size by PI and a reference range with 95% reliability were suggested.
The superoinferior diameter of right lobe was 12.34±1.18cm in males and 11.07±0.93cm in females, and its reference range was 10.64~11.0cm for Group I, 11.78~12.12cm for Group II, and 13.02~13.84cm for Group III. The anteroposterior diameter(T) of left lobe was 5.93±1.09cm in males and 5.18±0.99cm in females, and its reference range was 4.77~5.17cm for Group I, 5.49~5.79cm for Group II, and 6.68~7.44cm for Group III. The transverse diameter was 3.51±0.60cm in male participants and 3.42±0.49cm in female participants and its reference range was 3.29~3.51cm for Group I, 3.36~3.55cm for Group II, and 3.52~4.0cm for Group III. The caudate lobe index was 11.65±2.88cm 2 in males and 9.62±2.18cm 2 in females and its reference range was 8.83~9.75cm 2 for Group I, 10.62~11.47cm 2 for Group II, and 11.89~14.26cm 2 for Group III.
As a basic measurement method of liver size, the present study suggests measuring the superoinferior diameter for right liver lobe, the anteroposterior diameter for left liver lobe, the transverse diameter for quadrate lobe, and the caudate lobe index for caudate lobe. It is expected that this method along with its relevant reference range can be used as useful indicators in determining hepatomegaly and liver atrophy upon the diagnosis and follow-up testing of diffuse liver disease.
목차
Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
키워드
해당간행물 수록 논문
- 유방전용감마카메라에서 유방 보형물이 영상에 미치는 영향에 관한 고찰
- RESRAD 코드를 활용한 규제해제 폐기물 소각처분에 대한 안정성 평가
- 디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측
- 3차원 프린팅 적층가공 방식에서 매질 내부 충전이 초음파 속도와 감쇠에 미치는 영향
- 공개용과 상업용 DICOM STL 파일변환 프로그램으로 출력한 삼차원 프린팅 쇄골 골절 모델의 품질비교
- 소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가
- 요로결석 위치 진단에 대한 복부자세 변화에 따른 연구
- 이중 에너지 X선 흡수계측법을 이용하여 폐경기간에 따른 골밀도 변화의 상관관계 연구
- T2 이완시간의 정량적 평가에 있어서 Maximum TE의 설정 범위에 대한 연구 : 팬텀연구
- 초음파검사에 의한 간 크기 측정방법 및정상 성인의 체격지수별 참조범위
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)